520198-06 - VCM

Case IH 520198-06 - VCM – VCM: Cut-off solenoid supply circuit abnormally high current or short-circuited to ground

Issue description

The system's digital output (DOUT) detects that the electrical load connected to the cut-off solenoid is too high (drawing greater than 2.5 Amps) or that the circuit is short-circuited to ground.

Applies to these machines

  • MAGNUM AFS Connect
  • Magnum 400 AFS Connect

Check the cause

  1. Check the wiring harness connected to the cut-off solenoid's digital output (DOUT) for a short circuit to ground (GND).

  2. Verify the electrical load of the solenoid. An excessively high draw (greater than 2.5 Amps) usually points to an internally shorted solenoid coil.

  3. Verify the off-road safety check status. If this check fails due to the high current/short, electro-hydraulic steering will be disabled.

Repair steps

  1. Locate solenoid

    Locate the cut-off solenoid on the electrohydraulic steering valve assembly.

  2. Inspect wiring and connectors

    Disconnect the solenoid and inspect the wiring harness and connectors between the VCM and the cut-off solenoid for any signs of damage, chafing, or a direct short to ground.

  3. Test wiring harness

    Test the wiring harness independently of the solenoid to determine if the short to ground is in the wiring.

  4. Repair wiring

    If the wiring is shorted to ground, repair or replace the affected section of the harness.

  5. Replace solenoid

    If the wiring tests good, the issue is an internal short within the solenoid itself causing it to draw more than the 2.5A limit. Remove and replace the faulty cut-off solenoid.

Parts you might need

(1)
  • Electrohydraulic Steering Cut-off Solenoid

    Manufactured by Danfoss. Component of the PVED-CLS electrohydraulic steering valve sub-system (OSPE / EHi).

Get help to fix this fault by requesting a quote

Browse other Case IH codes