520241-13 - VCM

Case IH 520241-13 - VCM – VCM: Steering valve controller internal fault

Issue description

An internal controller fault indicates a hardware or software failure within the module managing the electrohydraulic steering valve, preventing it from accurately processing steering inputs or communicating on the CAN bus.

Applies to these machines

  • MAGNUM AFS Connect
  • Steiger 370 AFS Connect
  • Steiger 420 AFS Connect
  • Steiger 470 AFS Connect
  • Steiger 580 AFS Connect

Check the cause

  1. Ensure the steering valve is supplied with sufficient hydraulic oil flow.

  2. Assure that all air has been bled from the steering system by turning the steering wheel fully left, then fully right, a minimum of 10 times.

  3. Verify that no abnormal noise or vibration occurs when steering.

  4. Check the wiring of the chassis CAN data connection and the related electrical connectors between the ECU and the steering valve for shorts or open circuits.

Repair steps

  1. Relieve hydraulic pressure

    Relieve all hydraulic pressure from the steering system before disconnecting any lines.

  2. Disconnect power

    Disconnect the battery/power supply to the VCM.

  3. Disconnect harnesses

    Disconnect the CAN/electrical harnesses from the steering valve controller and the VCM.

  4. Replace component

    Replace the faulty component (VCM or Steering Valve).

  5. Perform calibration

    Perform a steering valve calibration routine. Calibration must be performed on an on-road surface (i.e., unpainted concrete or asphalt).

Parts you might need

(2)
  • VCM Controller

    55.024.540

    CONTROLLER, 4WD VCM, CVT. Fitment: Case IH Steiger AFS Connect models (Production Date Before 1 Mar 2022 noted on some catalogs).

  • Steering Control Valve

    Main Steering Control Valve or Electrohydraulic Steering Valve

Get help to fix this fault by requesting a quote

Browse other Case IH codes