520438-06 - BCM

Case IH 520438-06 - BCM – BCM: Field light memory 1 recall indicator fault

Issue description

Fault code 520438-06 indicates a fault with the 'Field light memory 1 recall indicator'. The control module detects an abnormal voltage or lack of continuity (either an open circuit or a direct short to ground) on the indicator's circuit.

Applies to these machines

  • MAGNUM AFS Connect
  • Case IH Magnum AFS Connect 180
  • Case IH Magnum AFS Connect 200
  • Case IH Magnum AFS Connect 220
  • Case IH Magnum AFS Connect 240
  • Case IH Magnum AFS Connect 250
  • Case IH Magnum AFS Connect 280
  • Case IH Magnum AFS Connect 310
  • Case IH Magnum AFS Connect 340
  • Case IH Magnum AFS Connect 380
  • Case IH Magnum AFS Connect 400
  • Case IH Steiger AFS Connect

Check the cause

  1. Verify the active fault code in the BCM using a diagnostic tool.

  2. Inspect the wiring harness connecting the BCM to the Field light memory 1 recall indicator for any chafing, pinched wires, or exposed copper that could cause a short to ground or an open circuit.

  3. Check the BCM connectors and the switch panel connectors for moisture, corrosion, or bent pins.

  4. Verify the BCM software version and configuration to ensure the module is communicating correctly.

Repair steps

  1. Turn off the ignition and disconnect the battery

    This prevents electrical damage.

  2. Access the Body Control Module (BCM) and the field light memory switch/indicator panel

    These are located inside the cab.

  3. Disconnect the harness

    Disconnect the harness at the switch and at the BCM.

  4. Test the specific circuit wire

    Using a multimeter, test the specific circuit wire for continuity to ground (to check for a short) and end-to-end continuity (to check for an open circuit).

  5. Repair or replace the harness

    If a short or break is found in the harness, repair the damaged section of the wire or replace the affected harness section.

  6. Test the indicator/switch

    If the harness tests good, test the indicator/switch itself for an internal short or failure. Replace the switch assembly if it is faulty.

  7. Reconnect components and clear codes

    Reconnect all components, restore battery power, and clear the fault codes from the BCM.

  8. Test the field light memory function

    Ensure the code does not return.

Parts you might need

(4)
  • Body Control Module (BCM)

    47896946

    OEM software part number

  • Body Control Module (BCM)

    90342472

    OEM software part number

  • Field light memory 1 recall indicator / switch

  • Wiring Harness

Get help to fix this fault by requesting a quote

Browse other Case IH codes