Case IH 520599-03 - BCM – BCM: High power voltage supply (circuit 'd') out of range - high
Issue description
The Body Control Module is detecting that the "High power voltage supply" (circuit 'd') is exceeding the maximum expected voltage threshold (out of range - high).
Applies to these machines
1 machine- MAGNUM AFS Connect
Check the cause
Verify the overall system battery voltage and alternator output to ensure the machine is not overcharging
Inspect the wiring harness connected to the BCM for any chafing or melting that could cause a short to battery power
Check the high-power supply pins at the BCM connector with a multimeter to confirm if the voltage is actually too high or if the BCM is reading it incorrectly
Repair steps
Repair wiring harness
If the harness is shorted, locate and repair the shorted wires.
Replace and reprogram BCM
If the voltage supply is normal but the BCM reports it as high, the BCM itself must be replaced and reprogrammed.
Parts you might need
(3)Body Control Module (BCM)
OEM Case IH / CNH Industrial
Main Cab/Chassis Wiring Harness
OEM Case IH / CNH Industrial
Alternator / Voltage Regulator
If system-wide overcharging is the cause
Get help to fix this fault by requesting a quote