522835-05 - PCM

Case IH 522835-05 - PCM – PCM: LAN-2 Open Circuit

Issue description

Current below normal or open circuit on the Local Area Network 2 communication line.

Applies to these machines

  • MAGNUM AFS Connect
  • Magnum AFS Connect series
  • Magnum 400 AFS Connect
  • Steiger AFS Connect tractors
  • Optum AFS Connect tractors
  • Puma AFS Connect tractors
  • Patriot 50 Series sprayers
  • Axial-Flow 250 series combines
  • Axial-Flow 260 series combines

Check the cause

  1. Turn the ignition switch OFF and disconnect the battery cable to ensure the system is fully powered down before probing network pins.

  2. Inspect the PCM connectors and the main harness for the LAN-2 branch for backed-out pins, corrosion, or physical wire chafing.

  3. Disconnect the PCM harness connector and the corresponding module connector on the LAN-2 line, then use a digital multimeter to check for continuity across the LAN-2 network wires.

  4. Ensure the PCM is receiving proper operating voltage and ground, and check for any blown fuses related to the PCM or network modules.

Repair steps

  1. Isolate the Break

    Based on the continuity test, trace the LAN-2 wiring harness to locate the exact point of the open circuit.

  2. Repair the Harness

    If a broken wire or damaged connector pin is found, repair the wiring harness using OEM-approved splicing methods or replace the damaged connector terminal.

  3. Reconnect and Secure

    Reconnect all network modules and the PCM. Ensure the connector locks are fully seated to prevent future vibration-induced open circuits.

  4. Test the Network

    Reconnect the battery and turn the ignition ON.

  5. Clear Codes

    Use the Case IH diagnostic tool (EST) or the AFS Pro display to clear the 522835-05 fault code.

  6. Module Replacement (If Necessary)

    If the wiring harness tests perfectly (no open circuits found in the physical wiring) and the code immediately returns, the internal LAN-2 transceiver within the PCM has likely failed. The PCM will need to be replaced and provisioned by a dealer.

Parts you might need

(2)
  • PCM Connectivity Module - 4G

    91764687

    Replacement requires dealer programming and EULA acceptance to activate cellular services and FieldOps connectivity.

  • PCM Connectivity Module - 4G

    51464591

    Alternative/Superseded Part Number. Replacement requires dealer programming and EULA acceptance to activate cellular services and FieldOps connectivity.

Get help to fix this fault by requesting a quote

Browse other Case IH codes