55012

Case IH 55012 – Implement control module / Pro 1200 display: Granular chemical meter sensor failure

Issue description

The granular chemical system sensors are not detecting product flow when the control system is turned on.

Applies to these machines

  • STX Steiger
  • Planters

Check the cause

  1. Inspect the granular chemical smart box to verify if it is simply empty

  2. Check the granular chemical meter device and its sensor for physical blockages, bridging of the chemical, or visible damage

Repair steps

  1. Verify product level

    Open the granular chemical smart box and verify it has adequate product. Refill if empty.

  2. Clear blockages

    Clear any blockages or clumped product in the meter housing.

  3. Diagnose meter device

    If the box is full and product is flowing but the code persists, the granular chemical meter device has failed.

  4. Disconnect wiring

    Disconnect the wiring harness from the affected row's meter device.

  5. Replace meter device

    Remove and replace the failed granular chemical meter device/sensor.

  6. Clear fault

    Reconnect the harness and cycle the implement control on the Pro 1200 display to clear the fault.

Parts you might need

(1)
  • Granular Chemical Meter Device / Granular Chemical Sensor

    Specific OEM part numbers for the meter device were not indexed in the available search results for this specific fault code.

Get help to fix this fault by requesting a quote

Browse other Case IH codes