Case IH 6013 – Tractor Control Unit (TCU): Steering pressure sensor below minimum voltage limit
Issue description
The voltage signal returning from the steering pressure sensor to the controller is too low. This indicates a short circuit to ground in the sensor or wiring, or a faulty Tractor Control Unit (TCU).
Applies to these machines
62 machines- Steiger T4B
- Steiger 280
- Steiger 330
- Steiger 335
- Steiger 350
- Steiger 370
- Steiger 380
- Steiger 385
- Steiger 400
- Steiger 420
- Steiger 430
- Steiger 435
- Steiger 450
- Steiger 470
- Steiger 480
- Steiger 485
- Steiger 500
- Steiger 530
- Steiger 535
- Steiger 540
- Steiger 550
- Steiger 580
- Steiger 600
- Steiger 620
- Quadtrac 370
- Quadtrac 420
- Quadtrac 450
- Quadtrac 470
- Quadtrac 500
- Quadtrac 540
- Quadtrac 550
- Quadtrac 580
- Quadtrac 600
- Quadtrac 620
- Rowtrac 370
- Rowtrac 420
- Rowtrac 450
- Rowtrac 470
- Rowtrac 500
- Rowtrac 540
- Rowtrac 550
- Rowtrac 580
- Rowtrac 600
- Rowtrac 620
- STX275
- STX280
- STX325
- STX330
- STX380
- STX430
- STX480
- STX530
- Magnum 235
- Magnum 250
- Magnum 260
- Magnum 280
- Magnum 290
- Magnum 310
- Magnum 315
- Magnum 340
- Magnum 370
- Magnum 380
Check the cause
Check for other active 5.0 V sensor low-voltage error codes. If present, diagnose those first as a shared 5V reference circuit might be shorted elsewhere.
Inspect the wiring harness and connectors between the steering pressure sensor and the TCU.
Ensure the connectors are fully seated, not damaged, the pins are in the correct position, and the terminal fit is tight.
Disconnect the sensor and the TCU and test the harness for continuity and shorts to ground.
Repair steps
Perform diagnostic checks
Perform the visual and electrical diagnostic checks on the wiring harness as outlined above.
Repair or replace wiring harness
If the wiring harness or connector is found to be damaged, chafed, or shorted to ground, repair the wiring or replace the steering pressure sensor wire harness.
Replace steering pressure sensor
If the wiring harness tests perfectly (good continuity, no shorts to ground, proper 5V supply), the steering pressure sensor itself has failed internally and must be replaced.
Install new sensor
Unplug the sensor, unthread it from the hydraulic port, and install the new sensor. Ensure the appropriate O-ring is used to prevent hydraulic leaks.
Reconnect wiring harness
Reconnect the wiring harness.
Clear fault codes
Clear the fault codes using an Electronic Service Tool (EST) or the tractor's diagnostic display, and operate the machine to verify the code does not return.
Parts you might need
(5)Steering Pressure Sensor
375644A1Also crosses to CNH part number 47901032
Steering Pressure Sensor
47901032Cross reference for 375644A1
Steering Pressure Sensor Wire Harness
87551744O-Ring
637-6311311.3mm ID x 2.2mm thick; depending on exact port fitment
O-Ring
637-630939.3mm ID x 2.2mm thick; depending on exact port fitment
Get help to fix this fault by requesting a quote