Case IH 6019 – PTO Controller: PTO Solenoid Coil is failed short circuit or shorted to +12 volts
Issue description
The system has detected an electrical fault where the Power Take-Off (PTO) solenoid coil has an internal short circuit, or the wiring harness supplying the solenoid has shorted directly to a 12-volt power source.
Applies to these machines
22 machines- MX Magnum
- MX210
- MX230
- MX255
- MX285
- 215
- 245
- 275
- 305
- TG Series
- STX425
- STX430
- STX450
- 485
- MX80C
- MX90C
- MX100
- MX110
- MX120
- MX135
- MX150
- MX170
Check the cause
Check for any other active fault codes (such as 10061). If others exist, follow their corresponding corrective actions first.
Remove the controller cover from the rear of the tractor to access the PTO controller.
Disconnect the black connector (C057) from the PTO controller.
Test the resistance of the PTO solenoid circuit directly at the PTO controller connector (C057) to determine if the short is present in the wiring harness.
Inspect the wiring circuit from the controller to the PTO solenoid for any rubbed, pinched, or damaged wires that could be shorting to a +12V source.
Repair steps
Power down the tractor and access the PTO controller at the rear of the machine.
Power down the tractor and access the PTO controller at the rear of the machine.
Disconnect the main harness connector (C057) and use a multimeter to measure the resistance of the PTO solenoid circuit.
Disconnect the main harness connector (C057) and use a multimeter to measure the resistance of the PTO solenoid circuit.
If a short is detected, trace the wiring harness down to the PTO solenoid valve. Disconnect the harness directly at the solenoid.
If a short is detected, trace the wiring harness down to the PTO solenoid valve. Disconnect the harness directly at the solenoid.
Measure the resistance of the PTO solenoid coil itself.
Measure the resistance of the PTO solenoid coil itself.
If the coil's resistance indicates an internal short circuit, the solenoid coil must be replaced. Remove the retaining hardware on the PTO valve and slide the failed coil off.
If the coil's resistance indicates an internal short circuit, the solenoid coil must be replaced. Remove the retaining hardware on the PTO valve and slide the failed coil off.
Install the new PTO solenoid coil and secure it.
Install the new PTO solenoid coil and secure it.
If the coil tests within specification, the short to +12V is located in the wiring harness between the solenoid and the controller. Locate the damaged section of the wire and repair or replace the harness.
If the coil tests within specification, the short to +12V is located in the wiring harness between the solenoid and the controller. Locate the damaged section of the wire and repair or replace the harness.
Reconnect all connectors, clear the fault codes from the system, and test the PTO engagement to verify the repair.
Reconnect all connectors, clear the fault codes from the system, and test the PTO engagement to verify the repair.
Parts you might need
(4)PTO Solenoid / Solenoid Valve PTO
180584A1Fits Case IH MX Series (MX80C through MX170) and various International/Case-IH tractors. Replaces older OEM part number 190638A1.
PTO Solenoid
190638A1Older OEM part number replaced by 180584A1.
PTO Solenoid
47658159Newer CNH Industrial part number for Case IH PTO solenoids.
PTO Solenoid Coil / PTO Solenoid Valve Assembly
Get help to fix this fault by requesting a quote