6912-04 - DEC

Case IH 6912-04 - DEC – Transmission Control Module (TCU): Transmission hydro motor speed sensor electrical circuit fault voltage below normal

Issue description

A low voltage condition in the electrical circuit of the transmission's hydro motor speed sensor, indicating the controller is receiving a signal voltage that has dropped below the acceptable threshold.

Applies to these machines

  • MAGNUM AFS Connect
  • Case IH Magnum series (e.g., Magnum 340)

Check the cause

  1. Check system voltage to ensure battery voltage has not dropped below 11.5 volts, verifying battery health and alternator output.

  2. Inspect plug connections and cables leading to the hydro motor speed sensor for corrosion, backed-out pins, or chafing that could cause a short to ground.

  3. Verify the sensor setting and ensure it is transmitting a valid frequency/voltage signal to the controller.

Repair steps

  1. Power Cycle

    Restart the vehicle to see if the error is an active or stored/pending fault.

  2. Harness Repair

    If the wiring inspection reveals a short to ground or broken wire (causing the low voltage reading), repair the affected section of the harness or replace the connector (e.g., 2-pole female connector).

  3. Sensor Replacement

    If the circuit tests good (proper reference voltage and ground from the module) but the fault persists, the hydro motor speed sensor itself has failed internally and must be replaced.

Parts you might need

(2)
  • Hydro Motor Speed Sensor (Access Cover / Sensor Assembly)

    47624853
  • 2-Pole Female Electrical Connector

    87695582

Get help to fix this fault by requesting a quote

Browse other Case IH codes