709-02 - ACM

Case IH 709-02 - ACM – ACM: Configurable switch 9 circuit fault

Issue description

A circuit fault related to configurable switch 9 on the armrest console. Exact OEM documentation for this specific code is unavailable, but it involves the Armrest Control Module (ACM).

Applies to these machines

  • MAGNUM AFS Connect
  • Case IH Magnum Series (180, 190, 200, 210, 220, 225, 235-340, 240 CVT)
  • Case IH Steiger Series (350 to 600 horsepower models)

Check the cause

  1. Physical operation of the configurable switches on the armrest console.

  2. Wiring harness connections between the specific switch and the Armrest Control Module (ACM) for opens, shorts to ground, or shorts to power.

  3. Live data from the ACM using a diagnostic tool (such as the Case IH Electronic Service Tool / EASY tool) to see if the switch state changes when toggled.

Repair steps

  1. Verify switch operation

    Verify the physical operation of the configurable switches on the armrest console.

  2. Check wiring harness

    Check the wiring harness connections between the specific switch and the Armrest Control Module (ACM) for opens, shorts to ground, or shorts to power.

  3. Read live data

    Use a diagnostic tool (such as the Case IH Electronic Service Tool / EASY tool) to read live data from the ACM to see if the switch state changes when toggled.

Parts you might need

(3)
  • Configurable Switch / Rocker Switch

  • Armrest Control Module (ACM)

  • Armrest Wiring Harness

Get help to fix this fault by requesting a quote

Browse other Case IH codes