Case IH 75 – Transmission Control Unit (TCU) or Central Control Unit (CCU): Shaft 3 speed sensor fault

Issue description

The control module is receiving an erratic signal, an out-of-range signal, or no signal at all from the speed sensor monitoring Shaft 3. The controller detects that the shaft speed does not match the expected parameters.

Applies to these machines

  • STX Steiger
  • Farmall 55A/C
  • Farmall 65A/C
  • Farmall 75A/C
  • Farmall 75N
  • Farmall 85C
  • Farmall 95C
  • Farmall 115U
  • Axial-Flow 2388
  • Steiger
  • Quadtrac
  • Magnum
  • Maxxum

Check the cause

  1. Check battery voltage with the engine running at 2000 RPM to ensure it is stable and not spiking above 15 Volts.

  2. Inspect the wiring harness and connectors between the Shaft 3 speed sensor and the ECU/CCU for damage, ensuring pins are tight and fully seated.

  3. Perform a continuity test on the wiring harness with a multimeter to rule out an open circuit or short to ground.

  4. Verify the sensor is mounted securely and has the correct air gap.

  5. Remove the sensor and inspect the magnetic tip for a heavy buildup of metallic debris or shavings that could blind the sensor.

Repair steps

  1. Power Down

    Turn off the machine, remove the key, and disconnect the battery to prevent electrical shorts.

  2. Locate the Sensor

    Locate the Shaft 3 speed sensor on the transmission housing or PTO housing (refer to the specific model's service manual for exact placement).

  3. Disconnect

    Unplug the electrical connector from the sensor harness.

  4. Remove

    Remove the retaining bolt holding the sensor in place. Carefully twist and pull the sensor out of the housing. Have a shop towel ready, as a small amount of transmission/hydraulic fluid may seep out.

  5. Install New Sensor

    Lubricate the O-ring on the new speed sensor with clean transmission fluid. Insert the sensor into the bore until fully seated.

  6. Secure

    Install the retaining bolt and torque to the specification listed in your model's service manual.

  7. Reconnect

    Plug the electrical connector back into the sensor, ensuring it clicks and locks into place.

  8. Clear Codes

    Reconnect the battery. Use the Case IH Electronic Service Tool (EST) to clear the inactive fault code 75 from the module's memory.

  9. Test Operation

    Start the tractor and return the machine to operation to verify the fault code does not return and the shaft speed registers correctly on the display.