Case IH 9022 – Engine Control Unit (ECU): 5Vdc Supply 2 defect
Issue description
The 5-volt reference circuit #2, which supplies power to various engine sensors, is operating outside of its allowable voltage range (HIGH > 5.2 V or LOW < 4.6 V).
Applies to these machines
4 machines- STX Steiger
- Puma series (165, 180, 195, 210, 225 CVX)
- Steiger series
- MX/TG series
Check the cause
Check for a steady 5.0 VDC at the sensors powered by the Supply 2 circuit
Inspect the wiring harness going to the 5V sensors for visible damage, chafing, or exposed wires that could cause a short to ground (LOW) or a short to battery (HIGH)
Disconnect sensors on the 5V Supply 2 circuit one by one to see if the voltage returns to the normal 4.6V–5.2V range to isolate a shorted sensor
Repair steps
Locate components
Turn off the machine and locate the Engine ECU and the sensors on the 5V Supply 2 circuit.
Inspect ECU pins
Disconnect the main harness from the ECU and check the pins for corrosion or damage.
Replace shorted sensor
If a specific sensor was identified as shorted during the diagnostic checks, replace that sensor.
Repair or replace wiring harness
If the wiring harness is damaged, repair the exposed/broken wires or replace the affected harness section.
Replace Engine ECU
If the wiring and sensors are intact but the ECU is still outputting incorrect voltage (>5.2V or <4.6V) directly at the pin, the Engine ECU itself may have an internal hardware failure and will require replacement.
Verify repair
Clear the fault codes and cycle the key to verify the repair.