Case IH ARM1119 – ARM: RECORD/PLAY Switch Failure
Issue description
The Armrest Controller (ARM) has detected a malfunction in the RECORD/PLAY switch. This switch is a critical component of the End of Row (EOR) or Headland Management Control (HMC) system. A failure prevents the system from properly recording or playing back automated sequences, such as raising or lowering implements and engaging or disengaging the PTO.
Applies to these machines
18 machines- MX Magnum
- Magnum 180
- Magnum 215
- Magnum 245
- Magnum 275
- Magnum 290
- Magnum 305
- Magnum 335
- Puma 145
- Puma 155
- Puma 160
- Puma 210
- Maxxum 110
- Maxxum 115
- Maxxum 125
- Maxxum 130
- Maxxum 140
- Steiger
Check the cause
Visually inspect the RECORD/PLAY switch on the armrest control panel for visible damage, excessive wear, or debris interfering with operation.
Verify correct operator procedure is being followed (e.g., pressing and holding the record button to activate recording mode) to rule out operator error.
Inspect wiring and connectors on the underside of the armrest control panel for loose connections, corrosion, or damaged wires.
Retrieve all fault codes from the diagnostic display to rule out broader power supply or communication issues with the armrest controller.
Use the Case IH Electronic Service Tool (EST) to monitor the switch status in real-time and verify if it is sending a signal to the controller.
Repair steps
Disconnect power
Disconnect the tractor's battery before beginning any work on electrical components to ensure safety.
Access the control panel
Remove the screws from the underside of the armrest console to remove the upper panel of the armrest.
Remove switch assembly
Disconnect the electrical connectors and remove the integrated control panel or switch block containing the RECORD/PLAY switch.
Install new control panel
Install the replacement control panel assembly and re-establish all electrical connections.
Reassemble and test
Reassemble the armrest console, reconnect the battery, and turn the key on. Test the RECORD/PLAY switch and EOR system. Calibrate armrest components through the diagnostic menu if necessary.
Parts you might need
(5)Armrest End-of-Row Control Switch / Integrated Control Panel
Not available as a separate component. The entire control panel assembly must be ordered based on specific tractor model and serial number.
ECU/panel (Puma 160)
84241064Example part number for Puma 160; varies significantly by tractor model and production year.
ECU/panel (Puma 160)
84241061Example part number for Puma 160; varies significantly by tractor model and production year.
- End-of-Row Step/Pause Switch87422017
Applicable to older MX210 Magnum models; may not be applicable to newer models logging the ARM1119 code.
Remanufactured Armrest Controller
84165726ROptional remanufactured unit; represents a more extensive and costly repair.
Get help to fix this fault by requesting a quote