ARM1119

Case IH ARM1119 – ARM: RECORD/PLAY Switch Failure

Issue description

The Armrest Controller (ARM) has detected a malfunction in the RECORD/PLAY switch. This switch is a critical component of the End of Row (EOR) or Headland Management Control (HMC) system. A failure prevents the system from properly recording or playing back automated sequences, such as raising or lowering implements and engaging or disengaging the PTO.

Applies to these machines

  • MX Magnum
  • Magnum 180
  • Magnum 215
  • Magnum 245
  • Magnum 275
  • Magnum 290
  • Magnum 305
  • Magnum 335
  • Puma 145
  • Puma 155
  • Puma 160
  • Puma 210
  • Maxxum 110
  • Maxxum 115
  • Maxxum 125
  • Maxxum 130
  • Maxxum 140
  • Steiger

Check the cause

  1. Visually inspect the RECORD/PLAY switch on the armrest control panel for visible damage, excessive wear, or debris interfering with operation.

  2. Verify correct operator procedure is being followed (e.g., pressing and holding the record button to activate recording mode) to rule out operator error.

  3. Inspect wiring and connectors on the underside of the armrest control panel for loose connections, corrosion, or damaged wires.

  4. Retrieve all fault codes from the diagnostic display to rule out broader power supply or communication issues with the armrest controller.

  5. Use the Case IH Electronic Service Tool (EST) to monitor the switch status in real-time and verify if it is sending a signal to the controller.

Repair steps

  1. Disconnect power

    Disconnect the tractor's battery before beginning any work on electrical components to ensure safety.

  2. Access the control panel

    Remove the screws from the underside of the armrest console to remove the upper panel of the armrest.

  3. Remove switch assembly

    Disconnect the electrical connectors and remove the integrated control panel or switch block containing the RECORD/PLAY switch.

  4. Install new control panel

    Install the replacement control panel assembly and re-establish all electrical connections.

  5. Reassemble and test

    Reassemble the armrest console, reconnect the battery, and turn the key on. Test the RECORD/PLAY switch and EOR system. Calibrate armrest components through the diagnostic menu if necessary.

Parts you might need

(5)
  • Armrest End-of-Row Control Switch / Integrated Control Panel

    Not available as a separate component. The entire control panel assembly must be ordered based on specific tractor model and serial number.

  • ECU/panel (Puma 160)

    84241064

    Example part number for Puma 160; varies significantly by tractor model and production year.

  • ECU/panel (Puma 160)

    84241061

    Example part number for Puma 160; varies significantly by tractor model and production year.

  • Applicable to older MX210 Magnum models; may not be applicable to newer models logging the ARM1119 code.

  • Remanufactured Armrest Controller

    84165726R

    Optional remanufactured unit; represents a more extensive and costly repair.

Get help to fix this fault by requesting a quote