ARM79
Case IH ARM79: HITCH LOAD command potentiometer is failed
Issue description
The HITCH LOAD command potentiometer has failed, which may affect the proper operation of the hitch system. This fault indicates a problem with the component responsible for transmitting the load command signal.
Check the cause
HITCH LOAD command potentiometer
the affected circuit
Repair steps
Inspect
Inspect the HITCH LOAD command potentiometer for visible damage or wear.
Test
Test the HITCH LOAD command potentiometer for proper functionality using the appropriate diagnostic tools.
Replace
If the HITCH LOAD command potentiometer is found to be faulty, replace it with a compatible component.
Parts you might need
(0)Get help to fix this fault by requesting a quote