ATC121
Case IH ATC121: Temperature Select Pot Circuit Issue
Issue description
The temperature select pot is experiencing an open or shorted condition to power, which may affect the proper operation of the temperature control system.
Check the cause
Temperature select pot
Wiring connected to the temperature select pot
Power supply to the temperature select pot
Repair steps
Inspect
Check the temperature select pot for physical damage or signs of overheating.
Test
Use a multimeter to test the resistance and continuity of the temperature select pot.
Inspect
Examine the wiring and connections to the temperature select pot for any signs of wear, corrosion, or disconnection.
Parts you might need
(0)Get help to fix this fault by requesting a quote