ATC131
Case IH ATC131: Low Pressure Switch (+) Input Shorted to Ground
Issue description
The low pressure switch (+) input is experiencing a short to ground, which may cause improper operation of the system it is monitoring.
Check the cause
Wiring connected to the low pressure switch (+) input
Connections at the low pressure switch
Circuit integrity between the low pressure switch and the controller
Repair steps
Inspect
Inspect the wiring connected to the low pressure switch (+) input for damage, wear, or contact with grounded surfaces.
Test
Test the connections at the low pressure switch to ensure they are secure and not causing a short to ground.
Verify
Verify the circuit integrity between the low pressure switch and the controller using a multimeter or continuity tester.
Parts you might need