DCU19001

Case IH DCU19001: Battery Voltage Sensing Signal High

Issue description

The system has detected a battery voltage sensing signal that is above the upper limit. This indicates an abnormal voltage level being reported by the electrical system.

Check the cause

  1. The battery voltage level

  2. The wiring and connections related to the voltage sensing circuit

  3. The component identified by this code

Repair steps

  1. Verify the battery voltage

    Use a multimeter to measure the battery voltage and compare it to the expected range.

  2. Inspect the wiring and connections

    Check for loose, damaged, or corroded wiring and connections related to the voltage sensing circuit.

  3. Test the component identified by this code

    Follow the service manual procedures to test the component responsible for the voltage sensing signal.