Case IH DCU19001: Battery Voltage Sensing Signal High
Issue description
The system has detected a battery voltage sensing signal that is above the upper limit. This indicates an abnormal voltage level being reported by the electrical system.
Check the cause
The battery voltage level
The wiring and connections related to the voltage sensing circuit
The component identified by this code
Repair steps
Verify the battery voltage
Use a multimeter to measure the battery voltage and compare it to the expected range.
Inspect the wiring and connections
Check for loose, damaged, or corroded wiring and connections related to the voltage sensing circuit.
Test the component identified by this code
Follow the service manual procedures to test the component responsible for the voltage sensing signal.
Parts you might need
(0)Get help to fix this fault by requesting a quote