Skip to main content
DCU19577

Case IH DCU19577 – DCU: UREA quantity not in range

Issue description

The Dosing Control Unit (DCU) has detected that the urea (DEF) quantity signal is outside the expected range. This is fundamentally a Controller Area Network (CAN bus) communication error regarding the 'E2SCR' receive frame, which carries data about the Selective Catalytic Reduction (SCR) system. The fault indicates that invalid or out-of-range data is being transmitted to the DCU, often due to sensor failure, wiring issues, or related SCR system faults.

Applies to these machines

  • Case IH Magnum 235 – 340 (Series 4)
  • Case IH Puma series tractors

Check the cause

  1. Verify if the fault code is active or stored, and perform a tractor reboot to clear potential intermittent communication glitches

  2. Check the urea (DEF) tank to ensure it is not empty and the fluid is free of contamination or crystallization

  3. Check for other active SCR or CAN-related fault codes, specifically urea level (19101, 19102) or temperature (19109, 19110) codes

  4. Inspect the wiring harness and connectors between the urea tank/sensor assembly and the DCU for chafing, corrosion, moisture, bent pins, or poor ground connections

  5. Test the CAN bus wiring for continuity and shorts using a multimeter, or monitor live CAN data using a diagnostic tool like EST or Jaltest

  6. Inspect the DEF tank heater coolant control valve to ensure it is not stuck open and overheating the DEF

Repair steps

  1. Address basic DEF issues

    Fill the tank with fresh, high-quality DEF. If other related fault codes (like level or temperature sensor codes) are present, diagnose and repair them first as they may be the root cause.

  2. Repair wiring and connectors

    Repair or replace any damaged sections of the wiring harness found during inspection. Clean corroded connectors and ensure all pins have a secure connection.

  3. Replace urea sensor assembly

    If diagnostic checks isolate the failure to the urea sensor assembly (which includes level, quality, and temperature sensors), replace the unit.

  4. Replace Dosing Control Unit (DCU)

    If all wiring, sensors, and connections are verified good and the fault persists, replace the DCU as a last resort.

  5. Clear codes and verify

    Use a diagnostic tool to clear all fault codes. Operate the machine under normal conditions to verify the communication error does not return.

Parts you might need

(5)

Get help to fix this fault by requesting a quote

Browse other Case IH codes