Case IH EHR4218 – EHR: Rear Remote No. 3 - Valve Spool Not Calibrated
Issue description
The electronic control system has detected that the spool for the #3 rear electro-hydraulic remote (EHR) valve is not calibrated. The controller has lost the stored values for the valve's neutral position and/or its full extend and retract positions. This can be triggered if the control lever is not in its neutral position during tractor startup, or if calibration data is lost or corrupted, which will affect the proper operation of the associated hydraulic function.
Applies to these machines
10 machines- Magnum 235
- Magnum 290
- Magnum 340
- Puma 140
- Puma 165
- Puma 225
- Steiger 385
- Steiger 425
- Steiger 430
- Maxxum
Check the cause
Confirm operator procedure: Ensure the operator is not holding the #3 remote lever out of its neutral position when starting the tractor
Check for other faults: Review the tractor's fault code memory for any other active or stored codes related to the armrest controller, CAN bus, or power supply
Inspect wiring: Visually inspect the wiring harness leading to the #3 remote valve at the rear of the tractor for damage, corrosion, or loose connections (particularly in articulation areas on 4WD tractors)
Check lever 'feel': Gently wiggle the #3 remote paddle switch. If slight movements cause the fault to appear or disappear, it may indicate a failing potentiometer within the lever
Repair steps
Warm hydraulic oil
Operate the tractor to warm the hydraulic fluid to at least 50°C (122°F) for best calibration results.
Enter Service/Programming Mode
Turn the tractor key on while pressing and holding the 'Program' button on the A-post or armrest console.
Navigate to Calibration Menu
Use the arrow or scroll keys to find the 'ARM' (Armrest) or 'AUX' (Auxiliary) section, then select 'AUX LEVER' or a similar description for lever calibration.
Perform lever calibration
Follow on-screen prompts: Move all remote levers one at a time to their full rearward (extend/lift) detent position and press program. Then move them to their full forward (retract/lower) detent position (not float) and press program.
Save and cycle power
Navigate to 'EXIT' or 'SAVE' and press the program button. Turn the tractor key off and wait for at least 30 seconds to ensure the controller stores the new calibration values, then restart and test.
Replace armrest lever potentiometer
If calibration fails or does not hold, replace the armrest lever potentiometer, as it may have a dead spot or be worn out in the neutral position.
Replace EHR valve solenoid or assembly
If the lever is functioning properly but the fault persists, replace the EHR valve solenoid/pilot head or the entire rear remote valve assembly. Recalibrate the system after installation.
Parts you might need
(12)- Armrest Lever Potentiometer87605245
Replaces multiple numbers. Fits a variety of Magnum, Maxxum, and Steiger models.
- Armrest Lever PotentiometerA186061
Fits a variety of Magnum, Maxxum, and Steiger models.
- Armrest Lever Potentiometer92265125
Fits a variety of Magnum, Maxxum, and Steiger models.
- EHR Valve Solenoid87681738
Fits some Magnum and Puma models.
- EHR Valve Solenoid1958120C1
Fits some Magnum and Puma models.
- EHR Valve Solenoid87472229
Fits some Magnum and Puma models.
- Rear Remote Valve Assembly84230181
Fits some Maxxum and Puma models.
Rear Remote Valve Assembly
47595558Fits some Magnum and Steiger models.
Rear Remote Valve Assembly
87486189Fits some Magnum and Steiger models.
Rear Remote Valve Assembly
A169029Fits older models.
Remote Valve Main Spool
47429154Updated spool released by Case IH to fix erratic flow/surging issues on EHR valves, which may be relevant if the valve is being rebuilt.
EHR Control Valve Wiring Harness (4 Spool)
84151662Fitment: Case IH Steiger 350-620 models.
Get help to fix this fault by requesting a quote