EHR4219

Case IH EHR4219 – EHR (ARM / XCM): Rear Remote No.4 Valve Spool Not Calibrated

Issue description

This code indicates that the control system does not have a valid calibration saved for the 4th rear auxiliary hydraulic remote valve. This can happen if the calibration data is lost, if a new uncalibrated controller/valve was installed, or if a hardware failure (such as a faulty armrest potentiometer or sticking valve spool) is preventing the system from successfully completing the calibration sweep.

Applies to these machines

  • Magnum 235
  • Magnum 305
  • Magnum 340
  • Puma 140
  • Puma 155
  • Puma 160
  • Puma 165
  • Puma 180
  • Puma 195
  • Puma 210
  • Puma 225 CVX
  • Steiger Series
  • Quadtrac Series

Check the cause

  1. Inspect the wiring harness and electrical connectors leading to the number 4 remote valve for damage, corrosion, or loose connections (pay close attention to the articulation point on articulating tractors for chafing)

  2. Check for other active fault codes, as a failing potentiometer in the armrest control lever can sometimes trigger this fault

  3. Inspect the valve and its connections for any hydraulic fluid leaks

  4. Ensure the hydraulic fluid is warmed to at least 50-60°C (140°F) before attempting calibration, as temperature affects the process

Repair steps

  1. Armrest Control Calibration

    With the key off, press and hold the 'program' key on the armrest. While holding the program key, turn the ignition key to the 'on' position.

  2. Navigate to Calibration Menu

    Use the arrow keys to scroll through the menu to 'ARM' (or a similar armrest setting) and select it. Scroll to the auxiliary lever ('ox lever') calibration option and select it.

  3. Perform Lever Calibration

    Follow the on-screen instructions, which typically involve moving the remote levers one at a time to their full forward and rearward positions. Once complete, exit the menu, turn the key off, wait 30 seconds, and restart the tractor to test.

  4. EHR Valve Calibration (Diagnostic Tool)

    If armrest calibration fails, warm the hydraulic fluid to the recommended temperature. Connect the Case IH diagnostic tool (calibration cable) to the diagnostic port (often located near the passenger seat or under the cab), navigate to the EHR calibration settings in the software, and follow the guided process for each valve.

  5. EHR Valve Addressing (For New Valves)

    If a new valve has been installed, it must be addressed. Turn the key on, enter the 'H' menu, and navigate to the 'HL' function. Connect each remote valve one at a time until an audible tone is heard. Activate the number one timer switch three times until the display shows 'end', then turn the key off to save.

  6. Replace Faulty Components

    If calibration repeatedly fails, it indicates a faulty component. Replace the armrest lever potentiometer or the valve solenoid as indicated by diagnostics.

Parts you might need

(12)
  • Remote Control Valve Assembly

    84398218

    Example part number for Puma series

  • Example part number for Maxxum/Puma series

  • Remote Control Valve Assembly

    A169029

    Example part number for various models

  • Example part number for 5100/5200 series

  • Control lever sensor, replaces multiple older numbers

  • Example part number for older Magnum series

  • Example part number for older Magnum series, replaces 111448A1, A186003

  • Highly specific to the fitted valve

  • Highly specific to the fitted valve

  • Highly specific to the fitted valve

  • Remote Valve Main Spool (Updated)

    47429154

    Updated spool featuring an additional hydraulic oil bleed to resolve surging/erratic flow issues.

  • Generic fitment example; exact part number varies heavily by armrest generation and tractor model.