Case IH EHR4351 – ACM: Rear Remote No.7 - Valve Spool Not Calibrated
Issue description
The control system has detected that the spool for the seventh rear hydraulic remote valve is not synchronized with its control lever. This loss of calibration means the Armrest Control Module (ACM) cannot accurately determine the position of the valve, which can lead to erratic or non-functional operation of the hydraulic circuit. The issue is often accompanied by an EHR fault message on the A-post display and the hydraulic system may become unresponsive until the tractor is restarted.
Applies to these machines
17 machines- Magnum 180
- Magnum 210
- Magnum 245
- Magnum 275
- Magnum 290
- Magnum 315
- Magnum 380
- Steiger 385
- Steiger 425
- Steiger 430
- Steiger 480
- Quadtrac 385
- Quadtrac 425
- Quadtrac 430
- Quadtrac 480
- Puma Series
- Maxxum Series
Check the cause
Verify the fault code in the tractor's diagnostic menu on the A-post or Pro 700 display to confirm EHR4351 is active or stored.
Check for other active fault codes that may point to an underlying issue, such as a communication failure or low voltage.
Inspect the wiring harness and connectors between the armrest control lever, the Armrest Control Module, and the number 7 remote valve at the rear of the tractor. Look for wear, cracks, or damage, especially in articulation areas on 4WD tractors.
Observe system behavior by wiggling the control lever for remote #7. If slight movements cause the fault to appear or disappear, it strongly suggests a failing potentiometer within the lever assembly.
Repair steps
Enter Calibration Mode
With the tractor key in the 'ON' position (engine off), press and hold the 'PROG' (program) button on the A-post.
Navigate to Armrest Calibration
Use the arrow keys or control knob to scroll through the menu until you find the 'ARM' or 'ARMREST' section, then select it.
Select Auxiliary Lever Calibration
Scroll to the auxiliary lever or remote calibration menu (may be listed as 'AUX LEVER' or 'REM CAL') and enter it.
Calibrate Extend Position
The screen will show 'AUX EXTEND'. Pull back on all the remote levers one at a time and latch them in the rear detent position. The display should register each one. Press the program button to continue.
Calibrate Retract Position
The screen will show 'AUX RETRACT'. Push all remote levers forward into the front detent position (do not push into the float position). The display will register each lever movement. Press the program button to continue.
Exit and Save Calibration
Scroll through the menu to 'EXIT' and press the program button. Turn the tractor's key to the 'OFF' position and wait for at least 30 seconds to allow the new calibration values to be stored in the controller's memory. Start the tractor and test remote #7.
Access Lever Assembly (If calibration fails)
If calibration does not resolve the fault, the potentiometer is likely failing. Remove the plastic handle from the top of the control lever by pulling it straight up. Remove the surrounding trim or skirting on the armrest to access the mounting screws.
Replace Potentiometer
Remove the two screws securing the lever component from underneath the armrest control panel. Lower the component, disconnect the electrical connector, and install the new potentiometer/lever assembly. Secure with screws and reinstall trim.
Recalibrate New Component
After replacing the potentiometer, the calibration procedure (Steps 1-6) must be performed again to synchronize the new component with the control system.
Parts you might need
(4)Supersedes multiple part numbers for Case IH & Ford New Holland tractors
Fits various Case IH Magnum, Maxxum, and Steiger models
Replaces part number A186003; fits several 7100-series Magnum tractors
- Armrest Control Module (ACM) ECU48068685
Electronic Control Unit for the Armrest Control Module
Get help to fix this fault by requesting a quote