Case IH EHR4354 – EHR, ARM, or Vehicle Control Module: EHR FB 1 Low Err
Issue description
The Electronic Hitch Control (EHR) module has detected a low voltage condition in the circuit for the Electronic Hydraulic Remote (EHR) valve number 1. This typically indicates a short circuit to ground or an open circuit in the solenoid wiring, which prevents the proper function of the associated hydraulic remote.
Applies to these machines
3 machines- Steiger 400
- CIH 550 Quadtrac
- Magnum 290
Check the cause
Inspect the main wiring harness for damage, particularly in the articulation area and at 'P' clamps on articulated models.
Check the electrical connectors on the #1 remote hydraulic valve solenoids for secure connection, corrosion, bent pins, or loose wires.
Visually inspect the top and bottom solenoids on the #1 remote valve for physical damage.
Swap the electrical connector from the suspect #1 valve solenoid to an adjacent, functioning remote valve solenoid. If the fault code changes to the new valve number, the solenoid is faulty. If EHR4354 remains, the issue is in the wiring harness.
Repair steps
Clean and inspect connectors
Locate the bank of EHR remote valves at the rear of the tractor. Disconnect the electrical connectors for the #1 remote valve, clean with electrical contact cleaner, and inspect pins and seals.
Repair wiring harness
If harness damage is found (especially near the articulation joint), splice in a new section of wire, solder the connections, and seal with heat-shrink tubing to prevent moisture ingress. Replace the entire harness if damage is extensive.
Replace solenoid
If the solenoid is isolated as the fault, unscrew it from the hydraulic valve block (expect minor oil leakage). Install the new solenoid ensuring O-rings and seals are correctly seated, then reconnect the electrical connector.
Clear codes and calibrate
Clear the fault codes using a diagnostic tool or the tractor's diagnostic menu. Operate the #1 remote to verify the repair. Perform a calibration of the EHR valves if required after replacement.
Parts you might need
(6)EHR Control Valve Wire Harness
84151662For Quadtrac models. Verify fitment by serial number.
EHR Control Valve Wire Harness
51618178For Quadtrac models. Verify fitment by serial number.
- EHR Valve Solenoid87472229
Verify correct part with dealer using tractor serial number.
- EHR Valve Solenoid1958120C1
Verify correct part with dealer using tractor serial number.
- EHR Valve SolenoidJ928160
Verify correct part with dealer using tractor serial number.
- EHR Valve Solenoid118872A1
Verify correct part with dealer using tractor serial number.
Get help to fix this fault by requesting a quote