ENG2558
Case IH ENG2558: Auxiliary PWM Driver 1 Circuit Voltage too low
Issue description
The system has detected that the voltage in the Auxiliary PWM Driver 1 Circuit is below the expected level. This may affect the proper operation of the component connected to this circuit.
Check the cause
The power supply to the Auxiliary PWM Driver 1 Circuit
Connections and wiring associated with the Auxiliary PWM Driver 1 Circuit
The component identified by this code
Repair steps
Inspect
Inspect the power supply to the Auxiliary PWM Driver 1 Circuit for proper voltage and stability.
Check
Check the connections and wiring associated with the Auxiliary PWM Driver 1 Circuit for damage, corrosion, or loose contacts.
Test
Test the component identified by this code to ensure it is functioning correctly.
Parts you might need
(0)Get help to fix this fault by requesting a quote