Case IH F-520444-31 - CGR – CGR (CNH GNSS/Guidance Receiver): Software Upgrade Failure
Issue description
The display was attempting to flash or export software to the receiver, but communication with the receiver was lost mid-transfer (Destination unit removed).
Applies to these machines
4 machines- MAGNUM AFS Connect
- STEIGER AFS Connect
- Case IH Magnum AFS Connect (Models 180, 200, 220, 240, 250, 280, 310, 340, 380, and 400)
- Case IH Puma AFS Connect (Models 200, 215, 230)
Check the cause
Verify Physical Connections: Check the physical connection between the AFS Pro 1200 Display and the CGR (Vector Pro receiver).
Inspect the Harness: Inspect the CGR Serial Interface Cable for breaks, corrosion, or loose pins.
Check Diagnostic Tooling: Ensure your Electronic Service Tool (EST) is fully updated (e.g., EST 8.6.0.0 Update 2 or newer) and use the correct Type 2 (Green) diagnostic connector.
Voltage Drop Test: Ensure stable battery voltage to the cab and receiver.
Repair steps
Secure the Connection
Reconnect or secure the wiring harness at the roof receiver and the back of the display to ensure the "destination unit" is securely present on the network.
Replace Faulty Wiring
If continuity tests fail between the display and the receiver, replace the CGR Serial Interface Cable.
Re-attempt the Flash
Re-attempt the software upgrade using the EST or via a USB drive through the Display's "Data Management" screen. Ensure the machine remains running or on a stable battery maintainer, and do not unplug the receiver during the export.
Module Replacement
If the receiver's internal memory was permanently corrupted by the interrupted flash (bricked) and it will no longer accept a software push, the CGR module must be replaced and reprogrammed.
Parts you might need
(8)CGR (GNSS/Guidance Receiver - AFS Vector Pro)
91737688RRemanufactured Module
CGR (GNSS/Guidance Receiver - AFS Vector Pro)
91737688CCore
Base Vector Pro Receiver Kit
88.100.055[020]CGR (GNSS/Guidance Receiver)
48183185New Holland PLM Cygnus equivalent
CGR (GNSS/Guidance Receiver)
91737690New Holland PLM Cygnus equivalent
CGR Serial Interface Cable / Wire Harness
51629199CGR Software Package
51631366Depending on machine Stage/Tier
CGR Software Package
90336819Depending on machine Stage/Tier
Get help to fix this fault by requesting a quote