Case IH ICU14017 – ICU: Fuel Level Sensor Voltage Out of Range Low
Issue description
The electronic control system is receiving a voltage signal from the fuel tank sending unit that is below the minimum acceptable threshold (often below 0.125V). This condition typically points to a short-to-ground in the sensor's signal wire, a completely failed/shorted fuel level sensor, or a malfunctioning instrument cluster controller.
Applies to these machines
8 machines- Magnum 235
- Magnum 245
- Magnum 250
- Magnum 280
- Magnum 305
- Magnum 310
- Magnum 315
- Magnum 340
Check the cause
Visually inspect the wiring harness and connectors between the fuel level sensor and the instrument cluster for chafed or broken wires, corrosion, or loose connections (especially near the sending unit)
Check the fuel level sensor for a clean and secure ground connection, as a poor ground frequently causes incorrect readings
Test the circuit by grounding the signal wire from the sending unit with the ignition on (the fuel gauge should show a full reading on some models)
Use a multimeter to check for proper voltage at the fuel level sensor's input connector (refer to the service manual for specifications); a lower than specified voltage could indicate a problem with the wiring from the battery
Test the fuel level sensor resistance with a multimeter (set to Ohms) by disconnecting the electrical connector, connecting leads to the signal and ground terminals, and manually moving the float arm from empty to full; the reading should change smoothly without erratic jumps or open circuits
Repair steps
Disconnect battery
Disconnect the negative battery terminal to prevent electrical sparks, work in a well-ventilated area, and take all necessary precautions when working with the fuel system.
Access fuel sending unit
Locate the fuel sending unit on the fuel tank. Remove the access plate near the fuel filler neck, or drain and remove the fuel tank if necessary depending on the model.
Remove old sending unit
Disconnect the electrical connector and fuel lines. Clean the area to prevent debris from falling into the tank, remove the retaining ring or bolts, and carefully lift the old unit out.
Install new sending unit
Verify the new part matches the old one. Install with a new gasket or O-ring, ensuring proper alignment.
Reassemble components
Tighten the retaining ring or screws to manufacturer specifications (use a star pattern if screws are used to ensure a proper seal). Reconnect the electrical connector and fuel lines.
Verify repair
Reconnect the battery, turn the ignition on, verify the fuel gauge reads correctly, clear the ICU14017 fault code, and check for fuel leaks.
Parts you might need
(9)- Fuel Tank Level Sensor84237523
For Case IH Magnum 315 (Tier 4A) and New Holland T8.390 (Tier 4A)
- Fuel Sender Unit87731313
For Case IH Magnum 305 and as a genuine New Holland part
Fuel Tank Sender Unit
51457142For New Holland T8.350 (Tier 4B). Remanufactured version available as 51457142R. Replaces 47457712.
Remanufactured Fuel Sensor
47512674RFits a wide range of Case IH models including some Magnum 250, 280, and 310 (Tier 4B) tractors, as well as some combines. Original product: 47512674.
- Fuel Tank Level Sender Unit47416695
Option for New Holland T8.390 (Tier 4A)
Case IH Magnum (7100, 7200, 8900 series)
- Fuel Level Sensor Assembly60-6831T91
Case IH Steiger (9200 series)
- Fuel Sender Gasket104812C3
Case IH Steiger (9200 series)
- Fuel Tank Level Sensor84370298
Newer Case IH / New Holland Models
Get help to fix this fault by requesting a quote