Case IH INST10037 – PERF: Controller Memory Error: Implement Width Lost
Issue description
The Performance Monitor controller has experienced an internal memory defect or an intermittent power supply, leading to the loss of the stored implement width value. This affects the proper operation of the implement and the machine's ability to correctly recognize the implement's dimensions, which is critical for the accurate calculation of area worked, application rates, and guidance systems.
Applies to these machines
29 machines- Magnum 215
- Magnum 245
- Magnum 275
- Magnum 305
- Magnum 335
- MX180
- MX200
- MX220
- MX230
- MX240
- MX255
- MX270
- MX285
- STX275
- STX325
- STX330
- STX375
- STX380
- STX425
- STX430
- STX450
- STX480
- STX530
- MXM120
- MXM130
- MXM140
- MXM155
- MXM175
- MXM190
Check the cause
Verify controller power and ground by inspecting connector C062 for a solid connection to the battery, as intermittent power is a primary cause.
Check the implement width calibration on the Performance Monitor display (e.g., Pro 700) to see if the value has been dropped.
Check for associated communication loss fault codes (e.g., INST 12011, TRANS 12011) which could indicate a broader CAN bus data network wiring issue rather than a failed monitor.
Clear the fault code and restart the tractor to determine if the memory error is an intermittent glitch.
Repair steps
Access the Performance Monitor
Locate the Performance Monitor in the cab, typically found behind an access panel on the A-post.
Inspect Connector C062
Disconnect connector C062 from the Performance Monitor. Carefully inspect both the male and female sides for any signs of corrosion, backed-out pins, or damaged wires. Clean the connector pins if necessary and ensure a secure connection when re-installing.
Recalibrate Implement Width
Turn the tractor key to the 'On' position. Navigate to the implement setup page on the tractor's display (e.g., Pro 700). Select the active implement, re-enter the correct implement width and swath width values, and save the settings.
Clear Faults
Use the tractor's diagnostic menu to clear all active and stored fault codes.
Cycle Power
Turn the tractor's ignition completely off. Wait for 30 seconds to allow all controllers to power down, then restart the engine.
Verify Repair
Operate the machine to confirm that the fault code INST10037 does not return. If the fault code reappears immediately or after a short period, the Performance Monitor controller is likely defective and requires replacement.
Replace Performance Monitor
If the fault persists, replace the Performance Monitor controller. After installation, the implement width and other relevant performance data will need to be re-entered into the new unit.
Parts you might need
(10)Performance Monitor Controller (Reman)
87350683RFits various MX Magnum tractors including MX230, MX240, MX255, MX270
Performance Monitor Controller (Reman)
87520588RFits various Magnum (215, 245, 275, 305, 335) and Steiger (STX330, STX380, STX430, STX480, STX530) models
Performance Monitor Controller
87350681Listed for MX180, MX220, MX240, MX270 tractors
Performance Monitor Controller
87326721Listed for MX180, MX220, MX240, MX270 tractors
Performance Monitor Controller
87311114Listed for MX180, MX220, MX240, MX270 tractors
Performance Monitor Controller
87307898Listed for MX180, MX220, MX240, MX270 tractors
Performance Monitor Controller
87306365Listed for MX180, MX220, MX240, MX270 tractors
Performance Monitor Controller
1987567C1OEM monitor for various Case IH machinery
Performance Monitor Controller
48107311Monitor
Monitor
Get help to fix this fault by requesting a quote