NH2036
Case IH NH2036: Dump Solenoid Open Circuit
Issue description
The system has detected an open circuit in the dump solenoid. This indicates a failure in the electrical connection or the solenoid itself, preventing proper operation of the component.
Check the cause
Dump solenoid wiring
Dump solenoid connections
Dump solenoid functionality
Repair steps
Inspect
Check the wiring and connections of the dump solenoid for damage, corrosion, or loose contacts.
Test
Use a multimeter to test the continuity of the dump solenoid circuit.
Replace
If the dump solenoid is found to be faulty, replace it with a compatible component.
Parts you might need