NH3069
Case IH NH3069: Injector Solenoid Valve Cylinder 3 - SOURCE HIGH
Issue description
The fault code indicates that the injector solenoid valve for Cylinder 3 is receiving a high signal. This may suggest an issue with the signal input or the operation of the component itself.
Check the cause
The signal input to the injector solenoid valve Cylinder 3
The wiring and connections related to the injector solenoid valve Cylinder 3
Repair steps
Inspect the wiring and connections
Check for any damage, corrosion, or loose connections in the wiring and connectors associated with the injector solenoid valve Cylinder 3.
Test the signal input
Use a diagnostic tool to verify the signal input to the injector solenoid valve Cylinder 3 and ensure it is within the expected range.
Parts you might need
(0)Get help to fix this fault by requesting a quote