NH3102

Case IH NH3102: CP3 Fuel Pump Performance Issue

Issue description

The fault code indicates a problem with the CP3 fuel pump, likely due to low fuel supply or low output. It may also be related to a CP3 PWM fault, where the pulse width modulation signal is not within the expected range.

Check the cause

  1. Fuel filter restriction

  2. Fuel supply pressure to CP3

  3. CP3 output performance

  4. CP3 PWM signal in Atlas

Repair steps

  1. Inspect

    Check for fuel filter restriction and replace if necessary.

  2. Measure

    Verify fuel supply pressure to CP3 using appropriate tools.

  3. Test

    Evaluate CP3 output performance according to service manual procedures.

  4. Analyze

    Check CP3 PWM signal in Atlas, ensuring it meets the specified range (minimum 3% at engine idle, maximum 24% at full load).