NH4003

Case IH NH4003 – DV Module: AUX 1 Potentiometer Signal Out of Range

Issue description

The Directional Valve (DV) Module has detected a voltage signal from the number 1 auxiliary remote flow control potentiometer (AUX 1) that is either too high or too low, falling outside the expected operational range. This indicates a fault with the potentiometer itself, its wiring, or its connection to the control module, which prevents the system from determining the correct hydraulic flow to send to the first auxiliary remote valve.

Applies to these machines

  • Puma
  • Puma 125
  • Puma 160
  • Puma 165
  • Puma 180
  • Puma 195
  • Puma 210
  • Maxxum
  • Maxxum 140
  • Farmall
  • JX Series
  • Magnum
  • MXU Series

Check the cause

  1. Verify the paddle switch (lever) for the remote valve is in the neutral position at startup; try wiggling the paddle slightly upon startup to see if the fault temporarily clears

  2. Inspect the wiring harness and connectors between the armrest controls for the auxiliary hydraulics and the electro-hydraulic valve block for damage, corrosion, or loose connections

  3. Test the potentiometer's signal using a multimeter to check for correct voltage and resistance readings at the sensor's connector

  4. Recalibrate the auxiliary remote levers to teach the control module the correct voltage range for the neutral, forward, and rear positions of the potentiometer

Repair steps

  1. Prepare machine for service

    Park the tractor on a level surface, lower all implements, and turn off the engine. Relieve any residual hydraulic pressure by cycling the remote valve levers.

  2. Attempt lever calibration

    With the key off, press and hold the 'program' button on the A-post or armrest display. Turn the key to 'on', navigate to the 'ARM' or 'Armrest' menu, and select the 'Aux Lever' calibration. Move each remote lever to full forward and rearward positions (detents), pressing the program button to confirm each step (do not use float unless specified). Exit, turn key off, wait 30 seconds, and restart to check if the fault cleared.

  3. Replace faulty potentiometer

    If calibration fails or the code returns immediately, access the internal components of the armrest. Disconnect the wiring for the AUX 1 potentiometer, remove retaining hardware, and install a new genuine OEM potentiometer.

  4. Recalibrate system

    After replacing the potentiometer, reassemble the armrest and perform the lever calibration procedure again to ensure the new component is correctly recognized by the control module.

Parts you might need

(10)
  • OEM part for Farmall, JX Series, Magnum, Maxxum, and Puma series. Replaces 82007044, 82011878, 82017877, 82018521, 82021035, 82021037, 87543715, 87559698, 87559705, and 87605246.

  • Potentiometer

    47133194

    OEM part listed specifically for Maxxum 140.

  • Potentiometer

    55076

    Aftermarket part fitting Maxxum and Puma series.

  • OEM part for Maxxum and MXU series.

  • OEM part primarily for Magnum and Maxxum tractors.

  • replaces older numbers 122756A1, 122756A2

  • Armrest Control Switch assembly

    AS164041AP
  • common on older Magnum series like 7100/7200/8900