Case IH NH4040 – ARU: Supply Voltage Too Low
Issue description
The electrical voltage being supplied to the Arm Rest Unit (ARU) / DV Module has dropped below the minimum operating threshold of 8 Volts. When the voltage drops this low, the module cannot reliably process inputs from the operator controls (like the throttle, hitch controls, or remote valves) or communicate properly over the CAN bus network.
Applies to these machines
39 machines- Magnum 215
- Magnum 235
- Magnum 245
- Magnum 255
- Magnum 275
- Magnum 305
- Magnum 335
- Magnum 340
- MX180
- MX210
- MX215
- MX230
- MX240
- MX245
- MX255
- MX270
- MX275
- MX285
- MX305
- Puma 125
- Puma 140
- Puma 155
- Steiger 280
- Steiger 330
- Steiger 335
- Steiger 380
- Steiger 385
- Steiger 430
- Steiger 435
- Steiger 480
- Steiger 485
- Steiger 530
- Steiger 535
- STX280
- STX330
- STX380
- STX430
- STX480
- STX530
Check the cause
Verify that the tractor's battery is fully charged and the alternator is functioning correctly, as low overall system voltage can trigger this fault
Visually inspect the wiring harness connecting to the armrest controller for chafing, pinching, or damage, particularly where it passes near moving components like the seat
Inspect the main 12-pin Deutsch connector at the back of the armrest to ensure it is securely locked, and check pins and sockets for corrosion, moisture, or damage
With the key on, verify 12V power and a solid ground connection at the armrest controller's main connector
Perform a voltage drop test on both the power and ground circuits to identify high resistance in the wiring or connections
Check CAN bus integrity by measuring resistance between pins 'C' and 'D' on the diagnostic connector with the key off (should be 55-65 ohms)
Observe the green LED status light on the armrest controller board (flashing = powered and communicating; solid = power but no communication; off = no power)
Repair steps
Address basic electrical issues
Repair any identified issues with the wiring harness, connectors, power supply, or grounds. This may involve repairing harness sections, cleaning/replacing connector pins, or securing a new ground connection.
Check for intermittent faults
With the key on, wiggle the wiring harness and connectors to attempt to replicate the fault, which may be triggered by vibration.
Isolate the controller
If wiring and power are good, check for a significant voltage drop when the controller is plugged in. A large drop indicates an internal short in the module.
Replace and calibrate the controller
If the armrest controller is faulty, replace it. Handle the new unit with care to avoid static discharge damage. After installation, perform a calibration procedure for the armrest functions (such as hydraulic SCVs).
Parts you might need
(8)- Armrest Control Module87524858
Replaces 84161582. Fits various Case IH Magnum, MX, and Steiger models.
- Armrest Control Module48068685
Electronic Control Unit for Armrest Control Module.
- Armrest Control Module47443335
Armrest Control Module.
Armrest Control Module (Remanufactured)
84165726RFits MX210, MX230, MX255, MX285, and some Steiger models.
Armrest Control Module
399285A1Older Armrest Controller part number.
Arm Rest Module (ARU) / Electronic Control Unit
87308354CNew. Fitment specifically for Case IH Magnum MX series; exact part numbers will vary heavily depending on the specific tractor/combine model.
Arm Rest Module (ARU) / Electronic Control Unit
87308354RRemanufactured. Fitment specifically for Case IH Magnum MX series.
- Armrest Potentiometer141758046
If individual components are shorting the 5V reference.
Get help to fix this fault by requesting a quote