Case IH NH4104 – EHR: Remote No.1 Under Voltage
Issue description
The system has detected an under-voltage condition related to the No. 1 rear electro-hydraulic remote (EHR) valve. This indicates that the electrical power supplied to the components of the first remote valve has dropped below the specified range, logging a fault when the controller's supply voltage falls to near or at the 9.8-volt range. This typically points to a power supply issue, a failing solenoid, or a fault in the circuit associated with this remote.
Applies to these machines
20 machines- Magnum 235
- Magnum 250
- Magnum 260
- Magnum 280
- Magnum 290
- Magnum 310
- Magnum 340
- Magnum 370
- Magnum 380
- T8.275
- T8.300
- T8.320
- T8.330
- T8.350
- T8.360
- T8.380
- T8.390
- T8.410
- T8.420
- T8.435
Check the cause
Verify main battery and charging system voltage to ensure the overall tractor voltage is correct, as low system voltage can trigger under-voltage faults.
Inspect the wiring harness and connectors leading to the No. 1 remote valve (specifically connectors C340 at the valve and C054) for visible damage, corrosion, or loose connections.
Check for short circuits between the power supply wires and other terminals in the remote valve's electrical circuit.
Repair steps
Check controller power and ground
Verify that the remote hydraulic controller has the proper power supply and a solid ground connection. Check the voltage at cavities 1 and 12 of the controller connector.
Test solenoid resistance
Disconnect connector C340 from the No. 1 remote valve. Inspect and clean the pins. Using a multimeter, measure the resistance across pins 1 and 2 on the remote valve side. The resistance should be between 4 and 8 ohms. If higher than 10 ohms (open circuit) or less than 3 ohms (short circuit), replace the solenoid.
Check voltage at the solenoid
If the solenoid resistance is within the specified range, reconnect all connectors. Turn on the tractor and activate the No. 1 remote valve. Verify there is approximately 12 volts at the relevant pins (e.g., pin 6 of connector C054). If there is no voltage or significantly low voltage, and the wiring is confirmed good, the remote hydraulic controller may be faulty.
Replace faulty components
Based on the diagnostic results, replace the remote valve solenoid, repair or replace the damaged wiring harness, or replace the remote hydraulic controller.
Parts you might need
(13)- Remote Valve Solenoid84286799
Multi-function hydraulic solenoid valve. Verify fitment with tractor serial number.
Remote Valve Solenoid
84537085Supersedes 87383670 and 87383671. Multi-function hydraulic solenoid valve. Verify fitment with tractor serial number.
Remote Valve Solenoid
87383670Superseded by 84537085.
Remote Valve Solenoid
87383671Superseded by 84537085.
Remote Valve Solenoid
278506A2For older MX series which may have similar designs.
Remote Valve Assembly
47595558Right-hand remote valve assembly. Replacement is typically only necessary if the valve body itself is damaged.
Remote Valve Assembly
47434188Right-hand remote valve assembly.
Remote Valve Assembly
87486189Right-hand remote valve assembly.
- Remote Valve Assembly47595559
Associated with the Magnum 340 hydraulic remote valve.
Fits many Puma, Magnum, and T7/T7000 series
Fits Maxxum 115/125, Puma, and New Holland T6000 series
Fits Maxxum 115/125, Puma, and New Holland T6000 series
Hydraulic Coupler Cartridge (Aftermarket/Shoup)
SH47116Fits Magnum, Maxxum, Puma
Get help to fix this fault by requesting a quote