Case IH NH4181 – Armrest (ARM) or dedicated remote hydraulics controller: EHR Control No.4 Open Circuit
Issue description
The fault code indicates an open circuit in the electrical system of the number 4 Electronic Hydraulic Remote (EHR) valve. The control module has detected a loss of electrical connection to the solenoid that operates this specific remote valve. This suggests a break or disconnection in the wiring, a loose or corroded connector, or a failed solenoid coil.
Applies to these machines
3 machines- Puma
- Magnum
- Steiger
Check the cause
Carefully inspect the wiring harness leading to the number 4 remote hydraulic valve for signs of damage, such as chafing, cuts, or heat damage, paying close attention to articulation points on tractors with pivoting frames
Disconnect and inspect the electrical connector at the number 4 EHR valve solenoid for corrosion, bent or broken pins, and ensure the connector is securely seated
Check for intermittent issues during specific operations (such as turning at a headland) which might indicate a wiring harness issue
Swap the solenoid from valve number 4 with one from a functioning remote valve. If the fault code follows the solenoid to the new position, the solenoid is likely faulty. If the fault remains with the number 4 position, the issue is likely in the wiring or the controller
Repair steps
Isolate the issue
Using the diagnostic checks above, determine if the fault lies with the solenoid, the wiring, or the controller.
Repair wiring harness
If a break or damage is found in the wiring harness, repair the affected wires using appropriate connectors and sealing methods to prevent moisture ingress. Ensure the harness is properly secured and routed to prevent future damage.
Replace faulty solenoid
Relieve hydraulic pressure from the system. Disconnect the electrical connector, carefully unscrew and remove the solenoid from the hydraulic valve block (be prepared for residual fluid to leak). Install the new solenoid to the manufacturer's specification and reconnect the electrical connector.
Address controller issues
If the wiring and solenoid are confirmed to be in good condition, the issue may lie with the armrest controller. This is less common and may require a software update or replacement of the controller by a qualified technician. In some instances, a calibration procedure (such as an H8 procedure on some models) may be required after component replacement or to re-establish communication with the valves.
Parts you might need
(3)- EHR Remote Valve Solenoid118872A1
For some Case IH 5100/5200 series and MX series tractors (includes various supersessions)
- EHR Remote Valve Solenoid87540543
For some Steiger models
Remote Hydraulic Valve Assembly
A169029For a range of older Case and Case IH tractors