Case IH P202D – DCU, Denox Module, or PCM: Dynamic Urea Leakage Detected
Issue description
The emissions control system has identified a leak in the Diesel Exhaust Fluid (DEF) system by failing a pressure test. The control module activates the DEF pump to pressurize the lines and monitors pressure sensors; if the pressure drops unexpectedly or fails to reach the target, a leak is logged. This condition prevents the Selective Catalytic Reduction (SCR) system from correctly dosing DEF to neutralize NOx emissions, which will lead to engine power reduction (derate) and eventual shutdown.
Applies to these machines
30 machines- Steiger 370
- Steiger 420
- Steiger 450
- Steiger 470
- Steiger 500
- Steiger 540
- Steiger 580
- Steiger 620
- Quadtrac 370
- Quadtrac 420
- Quadtrac 450
- Quadtrac 470
- Quadtrac 500
- Quadtrac 540
- Quadtrac 580
- Quadtrac 620
- Magnum 290
- Combine 5150
- Combine 6150
- Combine 7150
- Combine 7240
- Combine 8240
- Combine 9240
- Sprayer 4440
- Sprayer 5550 Trident
- Titan 3040
- Titan 3540
- Titan 4040
- Titan 4540
- FR Series Forage Harvester
Check the cause
Record exact fault codes using the Case IH Electronic Service Tool (EST) to identify specific manufacturer codes (e.g., 19813, 19298) for precise failure mode details.
Check DEF quality using a refractometer to ensure a 32.5% urea concentration. Poor quality DEF can cause numerous SCR issues.
Visually inspect the DEF tank, supply/return lines, pump/module assembly, and injector nozzle for external leaks, which are indicated by a distinct white crystalline residue.
Run the Urea Dosing System Test (UDST) using the EST to verify if the system can achieve target pressure (4900 to 6200 mbar / 71 to 90 psi) and pull sufficient vacuum (-50 to -300 mbar).
Repair steps
Address External Leaks
If visual inspection reveals white crystal residue, replace the leaking component (e.g., a cracked line or loose fitting) and clean the affected area with deionized water.
Inspect for Internal Leaks (No Visible Leak)
If the UDST fails but there are no visible external leaks, check the DEF pickup (WEMA unit) for cracks or failed O-rings that allow air into the system, and inspect the DEF pump module for internal leaks where the pump runs but cannot build sufficient pressure.
Replace Faulty Components
Based on the diagnostic findings, replace the necessary parts. This is most often the DEF tank pickup/level sensor assembly or the entire DEF pump module.
Clear Fault Codes and Retest
After replacing parts, use the EST to clear all related fault codes.
Perform a "Heal" or Regeneration Cycle
Run the UDST again to confirm the repair. Operate the machine under a moderate to heavy load (30-90%) for a sustained period to get the exhaust temperature high enough for the SCR system to run its full diagnostic and clear any remaining derates or warnings.
Parts you might need
(4)DEF Pump / Dosing Module
5802855463Contains pump, pressure sensor, and control logic. Verify fitment by serial number.
DEF Tank Level/Quality/Temp Sensor (WEMA Unit)
47711889Includes suction tube prone to air leaks. Example part for Steiger 500.
- DEF Tank Filler Cap48024751
Replaces 84206552 for Steiger 500. Faulty cap can cause tank pressure issues.
DEF Injector / Dosing Valve
Inspect for crystallization.
Get help to fix this fault by requesting a quote