Case IH R14 – EHR (Electronic Hydraulic Remote) Control Unit or Central Controller (XCM): Valve 1 Supply Under Voltage/Over Voltage Or Output Stage Faulty Or Transducer Faulty Or Spool Neutral Error Or Spool Not Neutral Error
Issue description
A multi-condition fault code indicating a failure in the Electronic Hydraulic Remote (EHR) Valve 1 circuit or mechanics. The system has detected a voltage issue (under 8V or over 36/45V), an output stage/transducer fault, or a mechanical spool error (stuck or not in neutral).
Applies to these machines
11 machines- MXM
- MXM 120
- MXM 130
- MXM 135
- MXM 140
- MXM 150
- MXM 155
- MXM 165
- MXM 175
- MXM 180
- MXM 190
Check the cause
Test the voltage supply at the EHR Valve 1 connector to ensure it is receiving a stable 12V supply and is not dropping below 8V or surging.
Inspect the wiring harness between the EHR Valve 1 and the Central Controller (XCM) for chafing, open circuits, short circuits to ground, or corroded pins.
With the machine off and pressure relieved, check if the spool is physically jammed by debris.
Verify that the EHR valve is communicating properly with the controller via the tractor's H-Menu diagnostics.
Repair steps
Isolate the Fault
Swap the electrical connector from EHR Valve 1 to EHR Valve 2. If the fault code changes to R24 (Valve 2 Supply/Spool Error), the issue is internal to the valve itself. If the code remains R14, the issue is in the tractor's wiring harness or the XCM controller.
Repair Wiring
If the harness is faulty, repair the broken wires or replace the connector pigtail.
Valve Replacement/Rebuild
If the valve is the culprit (faulty transducer or stuck spool), remove the EHR Valve 1 assembly. You can attempt to replace the internal/external O-rings and clean the spool, but a failed internal transducer or output stage requires replacing the Electro-Hydraulic Valve Head or the entire spool valve assembly.
System Calibration
After repairing or replacing the valve, recalibrate the EHR system. Using the tractor's instrument cluster, enter the H-Menu (specifically the HL menu for EHR valve number reprogramming). Install a diagnostic test switch (Tool No. 380000488) and operate the No. 1 EHR Valve timer switch to activate the calibration procedure so the controller recognizes the new valve limits.
Parts you might need
(9)Electro-Hydraulic Spool Valve (EHR Valve) / Valve Head
87546169Complete Spool valve set including EHR control for CCLS hydraulic pumps
Electro-Hydraulic Spool Valve (EHR Valve)
84175671Alternative/Superseded CNH EHR Valve
Electro-Hydraulic Spool Valve (EHR Valve)
47532950Alternative/Superseded CNH EHR Valve
Electro-Hydraulic Spool Valve (EHR Valve)
47532954Alternative/Superseded CNH EHR Valve
Electro-Hydraulic Spool Valve (EHR Valve)
47532947Alternative/Superseded CNH EHR Valve
Electro-Hydraulic Spool Valve (EHR Valve)
5192188Alternative/Superseded CNH EHR Valve
Rebuilt Electro-Hydraulic Valve Head
MANHFF00362Breizelec rebuilt Electro-Hydraulic Valve Head
Internal O-ring kit
MADIFF00117Breizelec internal O-ring kit
Diagnostic test switch
380000488Required for system calibration
Get help to fix this fault by requesting a quote