Case IH t1A – Engine Controller / Engine ECU: Fuel Quantity Shut-Off, Shorted To High Source
Issue description
The electrical circuit controlling the fuel quantity shut-off valve (solenoid) has a short circuit to a high voltage source (typically battery voltage), which prevents the engine controller from properly regulating or shutting off the fuel supply.
Applies to these machines
16 machines- MXM
- MX Series
- MX100
- MX110
- MX120
- MX135
- MX150
- MX170
- MX175
- TG Series
- Puma
- TM Series
- TM115-TM165
- MXM120-MXM155
- CX50-CX100
- MX80C-MX100C
Check the cause
Inspect connectors at the fuel shut-off solenoid and the Engine ECU for damaged, bent, or corroded pins
Inspect the wiring harness routing between the Engine ECU and the fuel shut-off solenoid for rubbed-through insulation or melted wires
Using a multimeter, test the signal wire for the fuel shut-off valve to see if it is receiving unintended battery voltage (shorted to high source) when disconnected
Test the internal coil of the fuel shut-off solenoid to determine if it is internally shorted to power
Repair steps
Turn off the tractor and disconnect the battery
Turn off the tractor and disconnect the battery to prevent further electrical damage.
Locate the fuel quantity shut-off solenoid
Locate the fuel quantity shut-off solenoid on the fuel injection pump.
Disconnect the electrical connector
Disconnect the electrical connector from the solenoid.
Repair the damaged section of the harness
If the diagnostic tests revealed a wiring issue, repair the damaged section of the harness using a harness repair kit, ensuring correct pin removal and insertion.
Remove the faulty fuel shut-off solenoid
If the solenoid is internally shorted, unbolt and remove the faulty fuel shut-off solenoid from the injection pump.
Install the new fuel shut-off solenoid
Install the new fuel shut-off solenoid (note: updated mounting bolts may be required depending on the specific part revision).
Reconnect the electrical connector and battery
Reconnect the electrical connector, reconnect the battery, and clear the active fault codes.
Start the engine
Start the engine to verify the repair and ensure the code does not return.
Parts you might need
(9)Fuel Shut-Off Solenoid (12V)
87420952Fits Case IH MX100, MX110, MX120, MX135, MX150, and MX170/175 tractors.
Fuel Shut-Off Solenoid (12V)
87435487Fits Case IH MX100, MX110, MX120, MX135, MX150, and MX170/175 tractors.
Fuel Shut-Off Solenoid (12V)
J932529Fits Case IH MX100, MX110, MX120, MX135, MX150, and MX170/175 tractors.
Fuel Shut-Off Solenoid (12V)
J991167Fits Case IH MX100, MX110, MX120, MX135, MX150, and MX170/175 tractors.
Updated mounting bolts
J991132May be required for installation of the fuel shut-off solenoid.
Fuel Shut-Off Solenoid (12V)
218323A1Alternative OEM part. Fits Case IH CX50-CX100 and MX80C-MX100C models.
Fuel Shut-Off Solenoid (12V)
340521A1Alternative OEM part. Fits Case IH CX50-CX100 and MX80C-MX100C models.
Fuel Shut-Off Solenoid (12V)
7167620DAlternative OEM part. Fits Case IH CX50-CX100 and MX80C-MX100C models.
Fuel Shut-Off Solenoid (12V)
S.42699Aftermarket option (Sparex).
Get help to fix this fault by requesting a quote