TMF138

Case IH TMF138: Aux 4th Raise Solenoid Fault

Issue description

The Aux 4th Raise solenoid has failed in an open or short circuit condition. This fault prevents the solenoid from functioning properly, which may affect the operation of the associated system.

Check the cause

  1. Aux 4th Raise solenoid

  2. wiring connections to the Aux 4th Raise solenoid

  3. power supply to the Aux 4th Raise solenoid

Repair steps

  1. Inspect

    Check the physical condition of the Aux 4th Raise solenoid for visible damage or wear.

  2. Test

    Use a multimeter to test the resistance of the Aux 4th Raise solenoid. Compare the reading to the manufacturer's specifications.

  3. Check

    Verify all wiring connections to the Aux 4th Raise solenoid for looseness, corrosion, or damage.

  4. Test

    Check the power supply to the Aux 4th Raise solenoid to ensure it is receiving the correct voltage.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Case IH codes