Case IH TMF167 – TMF: Current Detected When PTO Driver Is Off
Issue description
The Tractor Multi-Function (TMF) controller is sensing electrical current in the PTO solenoid circuit even when the command to activate the PTO is not present. This indicates an unintended electrical pathway, such as a short circuit, is energizing the circuit. An active TMF167 fault may cause the system to disable the PTO to protect the powertrain.
Applies to these machines
14 machines- MX80C
- MX90C
- MX100C
- MX100
- MX110
- MX120
- MX135
- MX150
- MX170
- Magnum 215
- Magnum 245
- Magnum 275
- Magnum 305
- Magnum 335
Check the cause
Visually inspect the wiring harness leading to the PTO solenoid for signs of damage, chafed or melted insulation, pinched wires, or corrosion.
Disconnect the wiring harness from the PTO solenoid and examine the connector terminals for damage, corrosion, or moisture. Clean the connectors and ensure a secure fit.
Repair steps
Isolate the component
Disconnect the wiring harness from the PTO solenoid to separate the solenoid from the rest of the circuit.
Check for short to power
With the PTO solenoid disconnected and the tractor's key in the 'ON' position (engine off), use a multimeter to measure the voltage between the ground and the power pin in the wiring harness connector that leads back to the TMF controller. The expected result is 0 volts. If voltage is present, this indicates a short circuit in the wiring harness (contact with another power source), and the harness must be repaired or replaced.
Test the PTO solenoid
If there is no voltage in the harness (wiring is good), measure the resistance between the two terminals of the PTO solenoid. A typical PTO solenoid should have a resistance of approximately 8.5 - 9.7 ohms. If the reading is significantly outside this range, indicating an open or shorted coil, replace the faulty solenoid.
Final verification
After repairing the wiring or replacing the solenoid, clear any active fault codes. Operate the tractor and the PTO system to confirm that the fault does not return. A PTO calibration may be necessary after repairs.
Parts you might need
(18)- PTO Solenoid Valve180584A1
OEM part. Compatible with Case IH MX series.
PTO Solenoid Valve
190638A1OEM part. Compatible with Case IH MX series.
- PTO Solenoid Valve190639A1
OEM part. Compatible with Case IH MX series.
PTO Solenoid Valve
704451A1OEM part. Compatible with Case IH MX series.
PTO Solenoid Valve
55380Aftermarket part. Compatible with Case IH MX series.
- PTO Solenoid / Valve48055262
Common on Magnum, Maxxum, and Puma. Replaces older numbers: 5196873, 87739558, 87577678, 1931612
- PTO Solenoid / Valve5196873
Replaced by 48055262
- PTO Solenoid / Valve87739558
Replaced by 48055262
PTO Solenoid / Valve
87577678Replaced by 48055262
PTO Solenoid / Valve
1931612Replaced by 48055262
- PTO Solenoid / Valve5168052
Common on JX and Farmall series.
- PTO Solenoid / Valve5167139
Common on JX and Farmall series.
- PTO ON/OFF Command Switch47906615
Common modern Case IH PTO switch.
- PTO ON/OFF Command Switch82027012
Common on MXM series.
- PTO ON/OFF Command Switch82007112
Common on MXM series.
PTO ON/OFF Command Switch
87311258Common on MXU and Maxxum series.
- PTO ON/OFF Command Switch82029627
Common on MXU and Maxxum series.
- PTO ON/OFF Command Switch177500A2
PTO Neutral Safety Switch (CX series).
Get help to fix this fault by requesting a quote