Case IH TMF23: Two Draft Pin Sensors Failed
Issue description
The system has detected that two draft pin sensors have failed. This may affect the proper operation of the draft control system.
Check the cause
The condition of the two draft pin sensors
The wiring and connections to the draft pin sensors
The functionality of the component identified by this code
Repair steps
Inspect
Inspect the two draft pin sensors for physical damage or signs of failure.
Test
Test the two draft pin sensors to confirm their functionality.
Replace
If the sensors are confirmed to be faulty, replace the affected draft pin sensors.