Case IH U121 – Electronic Park Lock (EPL) module, Transmission Control Unit (TCU), or Vehicle Control Unit (VCU): Inclinometer calibration procedure not OK
Issue description
The tractor's onboard diagnostic system attempted to calibrate the inclinometer (the tilt/inclination sensor used for leveling, draft control, and electronic park lock systems) but the procedure failed to complete successfully or the sensor's readings were rejected.
Applies to these machines
16 machines- Puma 125
- Puma 130
- Puma 145
- Puma 160
- Puma 165
- Puma 180
- Puma 195
- Puma 210
- Puma 225 CVX
- Farmall 40
- Farmall 45
- Farmall 50
- Farmall 100
- Farmall 115U
- Maxxum
- Steiger
Check the cause
Verify the vehicle is completely stationary (a moving tractor will trigger a related U123 code)
Check the ground level to ensure the vehicle is parked on completely flat, level ground
Disconnect and remove any rear attachments or heavy implements that alter the tractor's resting stance and pitch
Verify the correct OEM wheels and tires are installed and properly inflated
Inspect the physical installation of the inclinometer to ensure it is securely mounted, not broken, and not installed crookedly
Repair steps
Relocate tractor
Relocate the tractor to a known flat, level concrete surface.
Disconnect implements
Disconnect all implements from the rear remotes and drop any heavy attachments.
Verify tires and wheels
Verify that tire pressures are even and wheel sizes match the manufacturer's specifications.
Inspect sensor mounting
Inspect the inclinometer sensor mounting on the chassis for damage, debris, or looseness. Secure the mounting hardware if necessary.
Navigate to Calibration Menu
Turn the key switch on and use the ICU/keypad (or the 'up', 'down', and 'menu' keys) to navigate to the 'H Menu' (Calibration Menu) for the transmission/EPL system.
Restart calibration
Restart the inclinometer calibration procedure as prompted by the cluster display.
Store calibration values
If the calibration completes successfully, turn the key switch to the OFF position to store the new calibration values in the module's memory.
Replace inclinometer if defective
If the calibration fails again with U121 (or U120), the inclinometer sensor itself is internally defective and must be replaced.
Install new inclinometer and recalibrate
Install the new inclinometer, ensure it is mounted perfectly flat to the bracket, and repeat the H-Menu calibration procedure.
Parts you might need
(1)Inclination Sensor / Inclinometer (5-Volt DC, Dual-Axis)
87026294Replaces legacy CNH part numbers 86556530 and 87718024. Universal 5-volt electronic inclination and automatic leveling safety sensor.
Get help to fix this fault by requesting a quote