U122

Case IH U122 – Electronic Draft Control (EDC) Module / Front Suspension Control Module / Full Power Shift Transmission (FPS) Controller: Inclinometer offset out of range

Issue description

This is a calibration error indicating that the electronic control system is receiving a baseline reading from the inclinometer (tilt/level sensor) that falls outside the acceptable parameters. Because the sensor's baseline is skewed, the system cannot establish a true "zero" or level reference, which prevents the successful completion of calibration routines.

Applies to these machines

  • Case IH Puma Series (165, 180, 195, 210, 225 CVX)
  • Case IH Magnum Series (MX210, MX230, MX255, MX285)
  • Case IH Farmall Series (40, 45, 50 CVT, 115U)
  • Case IH Steiger Series

Check the cause

  1. Check the Ground: Ensure the vehicle is parked on completely flat, level ground (preferably a concrete shop floor).

  2. Check for Attachments: Remove any rear attachments or heavy implements. The weight of an implement can alter the tractor's stance and throw off the inclinometer reading.

  3. Check the Wheels/Tires: Verify that the correct set of wheels is installed and that tire pressures are even. Incorrect tire sizes or mismatched inflation will physically tilt the tractor.

  4. Review Sensor Installation: Inspect the physical installation of the inclinometer sensor. Ensure the mounting bracket is not bent, loose, or installed backward.

Repair steps

  1. Relocate the Tractor

    Move the tractor to a verified flat and level surface.

  2. Strip the Machine

    Detach all rear implements and attachments.

  3. Verify Stance

    Check tire sizes and pressures to ensure the chassis is sitting perfectly level.

  4. Inspect the Sensor

    Locate the inclinometer sensor on the chassis. Inspect its mounting hardware. Tighten or adjust the installation if it is loose or crooked.

  5. Check Wiring

    Inspect the 3-wire polyurethane conductor cable and connector going to the inclinometer for any damage, corrosion, or loose pins (it operates on a 5-Volt reference).

  6. Re-Calibrate

    Re-run the calibration procedure (e.g., EDC, Suspension, or Transmission calibration) via the tractor's display or H-menu diagnostics.

  7. Replace Sensor

    If the tractor is perfectly level, the wiring is intact, and the calibration still fails with code U122, the inclinometer sensor has failed internally and must be replaced.

Parts you might need

(2)
  • Inclinometer Sensor / Inclination Sensor (5-Volt Dual-Axis)

    87026294

    Replaces legacy part numbers 86556530 and 87718024. This is a 5-Volt DC regulated sensor with a 5 mA maximum current draw. It manages both lateral (side-to-side) and longitudinal (fore-aft) chassis inclination tracking data.

  • Inclinometer Sensor / Inclination Sensor

    47130085

    Used on certain specialty/orchard models, superseding older serials.

Get help to fix this fault by requesting a quote

Browse other Case IH codes