CLAAS 7506h – ECM, CEBIS, or CIS+: Hand Accelerator Signal Voltage Too High

Issue description

The signal voltage provided by the hand accelerator (potentiometer) is higher than the specified maximum limit. The control unit is receiving an out-of-range voltage, which prevents the hand accelerator from functioning properly. This is typically caused by a fault within the sensor itself, such as a worn resistive track, or a wiring issue like a short to a power source.

Applies to these machines

  • Arion
  • Axion
  • Lexion

Check the cause

  1. Visually inspect the hand accelerator assembly and wiring harness for frayed wires, loose connections, corrosion, or moisture intrusion.

  2. Check for other active or stored fault codes that might indicate a broader issue with the sensor's power supply or ground circuit.

  3. Test the sensor's voltage output by back-probing the connector with a multimeter (key on, engine off). The voltage should change smoothly; a spike above the typical 5-volt reference confirms the fault.

  4. Test the sensor's resistance with a multimeter. Check total resistance across outer terminals and sweep resistance from the center wiper terminal for erratic readings or dropouts.

  5. Check the wiring harness between the sensor and control module for continuity and short circuits, specifically looking for a short to a power source.

Repair steps

  1. Disconnect the Battery

    To prevent any electrical damage, disconnect the negative terminal of the battery.

  2. Access the Hand Accelerator

    The hand accelerator is typically located on the operator's armrest or control console. It may be necessary to remove surrounding panels or trim to gain access to the component and its mounting hardware.

  3. Disconnect the Electrical Connector

    Carefully disconnect the wiring harness from the sensor.

  4. Remove the Old Sensor

    Unbolt and remove the faulty hand accelerator assembly from its mounting point.

  5. Install the New Sensor

    Mount the new hand accelerator sensor and ensure it is securely fastened.

  6. Reconnect the Electrical Connector

    Attach the wiring harness to the new sensor.

  7. Reassemble and Reconnect Battery

    Reinstall any panels that were removed and reconnect the battery.

  8. Calibration (If Required)

    Some electronic components may require calibration after installation. Check if there is a calibration procedure for the new hand accelerator within the machine's diagnostic or settings menu (e.g., in the CEBIS terminal).

  9. Clear Fault Codes and Test

    Start the machine, clear the fault code using a diagnostic tool, and operate the hand throttle to ensure it is functioning correctly and that the fault code does not reappear.

Parts you might need

(4)
  • Fits CLAAS Lexion Series Harvesters. Also listed as 0000-11-0210.

  • Potentiometer0000117800

    Fits CLAAS Combine Lexion.

  • Potentiometer - 5v

    0011110

    Fits Lexion. Also listed as 00111100.

  • Hand Accelerator Potentiometer

    Generic part name for Arion/Axion tractors. Verify exact part via CLAAS Parts Doc catalog using machine serial number.

Get help to fix this fault by requesting a quote

Browse other CLAAS codes