CLAAS 752Bh – MFA: Engine Speed Contact Voltage Fault

Issue description

The engine speed memory function is experiencing a fault due to an illogical or inconsistent signal from its switch on the multifunction armrest. The control module detects an 'incoherent contact', meaning the signal voltage is neither high nor low, or does not match the expected state of the switch. This renders the engine speed memory inactive and is typically caused by a faulty switch, poor electrical connection, or wiring issue.

Applies to these machines

  • Arion 510
  • Arion 640
  • Axion 810
  • Axion 850

Check the cause

  1. Review all active and stored codes using the CEBIS display or a diagnostic tool to identify any interacting faults

  2. Check harnesses and connectors associated with the MFA (A100) for damage, corrosion, or loose connections, paying special attention to moisture ingress in CAN bus connectors under the cab floor

  3. Inspect fuses related to the multifunction armrest and transmission computer (e.g., F19, F20, and F21 on Arion 640-510 models)

  4. Verify that the MFA (A100) module and the engine speed contact (S189) are receiving the correct voltage and have a solid ground connection

Repair steps

  1. Access engine speed contact

    Gain access to the internal components of the multifunction armrest and locate the engine speed contact/switch (S189).

  2. Test contact switch

    Using a multimeter, test the S189 switch for proper continuity and resistance. Check for short circuits to power or ground, and for open circuits.

  3. Inspect MFA module

    If the contact and wiring are in good condition, inspect the MFA (A100) module circuit board for visible signs of damage or corrosion. Further diagnosis of the module may require the CLAAS Diagnostic System (CDS).

  4. Replace faulty components

    Replace the engine speed contact (S189) if it fails testing. If the contact is functional but the fault persists, replace the MFA (A100) module.

  5. Clear codes and test

    Clear all fault codes from the system. Operate the tractor and the engine speed adjustment controls to ensure the fault does not reappear.

Parts you might need

(18)
  • Engine Speed Contact / Switch

    Located within the multifunction armrest (S189). Contact an authorized CLAAS dealer with the tractor's serial number for the exact OEM part.

  • Multifunction Armrest Module (A100)

    Contact an authorized CLAAS dealer with the tractor's serial number for the exact OEM part.

  • Inductive Engine RPM Speed Sensor

    06768350

    Reference part for CLAAS Lexion; likely not the cause of the 752Bh fault code.

  • Speed Sensor0014064950

    Reference part for CLAAS Lexion, Jaguar; likely not the cause of the 752Bh fault code.

  • Speed Sensor0000117991

    Reference part for CLAAS Lexion, Jaguar; likely not the cause of the 752Bh fault code.

  • Speed Sensor0000117992

    Reference part for CLAAS Lexion, Jaguar; likely not the cause of the 752Bh fault code.

  • Speed Sensor

    0011810

    Reference part for CLAAS Lexion 500/600/700 series; likely not the cause of the 752Bh fault code.

  • Speed Sensor

    00118100

    Reference part for CLAAS Lexion 500/600/700 series; likely not the cause of the 752Bh fault code.

  • Speed Sensor

    00118101

    Reference part for CLAAS Lexion 500/600/700 series; likely not the cause of the 752Bh fault code.

  • Speed Sensor0000118100

    Reference part for CLAAS Combine Harvester Header; likely not the cause of the 752Bh fault code.

  • Speed Sensor

    18219950

    Reference part for CLAAS Combine Harvester Header; likely not the cause of the 752Bh fault code.

  • Speed Sensor

    1821995

    Reference part for CLAAS Combine Harvester Header; likely not the cause of the 752Bh fault code.

  • Engine Speed Sensor

    011810

    CLAAS Original part.

  • Armrest Control Module

    6188430

    CLAAS Arm Rest.

  • Claas Module

    4990252

    Alternate module part number.

  • Armrest Control Module (Reman)

    84165726R

    Compatibility with CLAAS is not confirmed.

  • Armrest Control Module

    47443335

    Compatibility with CLAAS is not confirmed.

  • Electronic Control Unit for Armrest Control Module

    48068685

    Verify fitment by serial number.

Get help to fix this fault by requesting a quote