CLAAS 7580h – Claas Sfa A102 Suspended Axle Module: Cab Suspension Compressor Inoperative
Issue description
The cab suspension compressor is not operating as expected. The compressor (Y334) is inoperative 100 ms after the command from the SFA (A102). This may affect the ability to manage the cab’s position.
Check the cause
Supply voltage of the compressor between the 1 (+AVC) and 3 (ground) terminals
Command voltage of the compressor between the 2 (command) and 3 (ground) terminals
Active damping functionality
Repair steps
Check the supply voltage
Measure the voltage between the 1 (+AVC) and 3 (ground) terminals of the connector J489. The voltage must be 12V.
Check the command voltage
Measure the voltage between the 2 (command) and 3 (ground) terminals of the connector J489. The voltage must be 12V.
Verify active damping
Ensure the active damping system is functioning properly.
Parts you might need
(0)Get help to fix this fault by requesting a quote