7580h

CLAAS 7580h – Claas Sfa A102 Suspended Axle Module: Cab Suspension Compressor Inoperative

Issue description

The cab suspension compressor is not operating as expected. The compressor (Y334) is inoperative 100 ms after the command from the SFA (A102). This may affect the ability to manage the cab’s position.

Check the cause

  1. Supply voltage of the compressor between the 1 (+AVC) and 3 (ground) terminals

  2. Command voltage of the compressor between the 2 (command) and 3 (ground) terminals

  3. Active damping functionality

Repair steps

  1. Check the supply voltage

    Measure the voltage between the 1 (+AVC) and 3 (ground) terminals of the connector J489. The voltage must be 12V.

  2. Check the command voltage

    Measure the voltage between the 2 (command) and 3 (ground) terminals of the connector J489. The voltage must be 12V.

  3. Verify active damping

    Ensure the active damping system is functioning properly.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes