CLAAS 7580h: Cab Suspension Compressor Inoperative

Issue description

The cab suspension compressor (Y334) is inoperative. The supply voltage of the compressor is not detected between the 1 (+AVC) and 3 command of the SFA (A102) and between the 2 (command) and 3 (ground) terminals of the connector J489. The voltage should be 12V. The system is unable to manage the cab's position.

Check the cause

  1. The supply voltage between the 1 (+AVC) and 3 command of the SFA (A102)

  2. The supply voltage between the 2 (command) and 3 (ground) terminals of the connector J489

  3. The condition of the cab suspension compressor (Y334)

Repair steps

  1. Check the supply voltage

    Measure the voltage between the 1 (+AVC) and 3 command of the SFA (A102) and between the 2 (command) and 3 (ground) terminals of the connector J489. The voltage must be 12V.

  2. Inspect the cab suspension compressor

    Examine the cab suspension compressor (Y334) for signs of damage or malfunction.

  3. Verify the connection

    Ensure that the connector J489 is properly connected and free from corrosion or damage.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote