CLAAS 7582h – MFA: Compressor Running for 6 Minutes
Issue description
The air conditioning (A/C) compressor has operated continuously for a duration of 6 minutes without cycling off. This indicates an issue with the system's ability to cycle or shut off properly, which is a control system failure. The cycling function is designed to protect the compressor from overheating and the evaporator from freezing; continuous operation can lead to reduced cooling performance, component damage, and potential system failure.
Applies to these machines
9 machines- Lexion 400
- Lexion 500
- Lexion 700
- Jaguar 800
- Jaguar 900
- Axion 800
- Arion 400
- Arion 500
- Arion 600
Check the cause
Check refrigerant pressure for a low refrigerant level (primary cause) or an overcharged system
Inspect the high and low-pressure switches to ensure they are not stuck closed
Inspect the A/C compressor clutch relay to see if it is mechanically stuck or electrically shorted in the 'on' position
Check for electrical faults, including damaged wiring, corrosion, or loose pins at the compressor clutch, pressure switches, and control module
Repair steps
Connect diagnostic scanner
Use the CLAAS Diagnostic System (CDS) to read live data from the climate control module. Check the status of the A/C request and pressure switch readings to identify if the module is receiving incorrect data or failing to send the 'off' command.
Perform pressure test
Connect a manifold gauge set. With the engine off, check static pressure. Start the engine, turn A/C to max cool, and observe operating pressures. If low side pressure drops excessively without the compressor cycling off, it points to a control system issue or blockage. If pressures are out of normal range, address the refrigerant level first (find and repair leaks, do not just recharge).
Test A/C compressor relay
Locate the A/C clutch relay (often labeled 'MG CLT') in the fuse box. Swap it with an identical relay from a non-critical circuit (like the horn). If the compressor cycles correctly, replace the faulty relay. Alternatively, test the relay's coil and contacts with a multimeter.
Test pressure switches
Disconnect the electrical connector from the pressure switch. Use a multimeter set to continuity to test the switch. Normally closed low-pressure switches should show continuity with sufficient static pressure. If it fails this test despite correct system pressure, replace the switch.
Inspect HVAC control module
If all external components (relay, switches, wiring) and refrigerant pressures are correct, the climate control module may have a failed internal component preventing it from disengaging the compressor. This requires advanced diagnostic tools to confirm before replacement.
Parts you might need
(5)Air Conditioning Compressor
8807975Fits various Lexion and Jaguar models (CLAAS/Caterpillar).
- Air Conditioning Compressor000 625 994 0
Sanden, for Lexion 430-415.
A/C Compressor Clutch Relay
15-8733Common 4-pin 12V relay.
A/C Compressor Clutch Relay
520-4745For Caterpillar applications.
A/C Pressure Switch
High or low-pressure switch. Varies significantly by machine; consult specific parts catalog.
Get help to fix this fault by requesting a quote