75C2h

CLAAS 75C2h: TR1 (A57-1) Supply voltage measured on the forward gear solenoid valve when the driver is not controlled (setpoint PWM = 0)

Issue description

The system detects supply voltage on the forward gear solenoid valve when the driver is not controlling it, indicating a potential issue with the control signal or the valve itself. An audio warning is triggered, and an

Check the cause

  1. The forward gear solenoid valve for proper operation

  2. The wiring and connections to the forward gear solenoid valve

  3. The control signal from the driver to the forward gear solenoid valve

Repair steps

  1. Inspect the forward gear solenoid valve for signs of damage or malfunction

    Check for physical damage, wear, or obstruction that may prevent proper operation.

  2. Check the wiring and connections to the forward gear solenoid valve

    Ensure all connections are secure, free from corrosion, and properly insulated.

  3. Verify the control signal from the driver to the forward gear solenoid valve

    Use a diagnostic tool to confirm that the control signal is being sent correctly when the driver is not active.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote