75C4h
CLAAS 75C4h – Claas Tr1 A57 1 Transmission Module: High Current Measured on Forward Gear Solenoid Valve Return
Issue description
The actual current measured on the return of the forward gear solenoid valve is higher than the setpoint. This condition triggers an audio warning and requests an
Check the cause
The solenoid valve power supply harness for a possible 12 V short circuit
The resistance of the solenoid valve winding
Repair steps
Inspect
Check the solenoid valve power supply harness for a possible 12 V short circuit.
Measure
Measure the resistance of the solenoid valve winding.
Test
Use tool n° 60 05 033 249 to test the “Auto 5” module and replace it if required.