75C7h

CLAAS 75C7h – Claas Tr1 A57 1 Transmission Module: Reverse Gear Solenoid Valve Current Exceeds 1.4 A

Issue description

The current consumed by the reverse gear solenoid valve is greater than the maximum allowable value of 1.4 A. This may trigger an audio warning and request an

Check the cause

  1. The solenoid valve if 301/302 are not shown

  2. A possible 12 V short circuit on the solenoid valve power supply harness

  3. The resistance of the solenoid valve winding

Repair steps

  1. Check the solenoid valve

    If 301/302 are not shown, inspect the solenoid valve for faults.

  2. Inspect the power supply harness

    Look for a possible 12 V short circuit on the solenoid valve power supply harness.

  3. Measure the resistance of the solenoid valve winding

    Use appropriate tools to check the resistance of the solenoid valve winding.

  4. Test the “Auto 5” module

    Use tool n° 60 05 033 249 to test the “Auto 5” module and replace it if required.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes