CLAAS 75C8h – Claas Tr1 A57 1 Transmission Module: Forward Gear Solenoid Valve Return Current Below Setpoint
Issue description
The actual current measured on the forward gear solenoid valve return is less than the setpoint value. This may trigger an audio warning and request an
Check the cause
A possible open circuit in the solenoid valve supply harness
A possible short circuit to earth on the solenoid valve
The resistance of the solenoid valve winding
The “Auto 5” module using tool n° 60 05 033 249
Repair steps
Check for a possible open circuit in the solenoid valve supply harness
Inspect the wiring and connections related to the solenoid valve supply harness for any breaks or disconnections.
Check for a possible short circuit to earth on the solenoid valve
Inspect the solenoid valve for any signs of shorting to ground, including damaged insulation or foreign material.
Measure the resistance of the solenoid valve winding
Use a multimeter to measure the resistance of the solenoid valve winding and compare it to the expected value.
Use the “Auto 5” module with tool n° 60 05 033 249
Access the “Auto 5” module using the specified tool and check or change the configuration if required.
Parts you might need
(0)Get help to fix this fault by requesting a quote